5.3 DTC (LH SERIES)<br />

5.3.1 DESCRIPTION<br />

This series features a top chord made of two <strong>Hambro</strong><br />

sections, an open web of light channels or angles and a<br />

range of heavier bottom chord angles.<br />

<strong>Hambro</strong> composite long span floors provide greater<br />

economy for heavy service loads and longer spans with<br />

live load deflections less than half those of conventional<br />

systems.<br />

5.3.2 MATERIALS<br />

The <strong>Hambro</strong> top chord acts as a continuous shear connector.<br />

Bottom chord angles and web members are hot or cold<br />

rolled sections, minimum yield Fy = 380 MPa (55 ksi) and<br />

350 MPa (50 ksi) for rods.<br />

5.3.3 WEB GEOMETRY<br />

See below.<br />

5.3.4 JOIST SPACING<br />

Note the new standard spacing <strong>Hambro</strong> LH Series,<br />

1 285 mm (4’-2 5 /8”) center to center, which is obtained<br />

when using standard Rollbar ® (1 251 mm (4’-1 1 /4”)<br />

spacing plus 35 mm (1 3 /8”) web thickness).<br />

P 1<br />

(P 1 + VAR 1 ) /2<br />

P 1<br />

PRODUCT INFORMATION<br />

VAR 1<br />

Variable panel<br />

(Clear span – 12 mm or 1 /2”)<br />

Fig. 22<br />

DTC Web Geometry<br />

5.3.5 SPAN AND DEPTH<br />

Span: Up to 16 155 mm (53’-0”).<br />

Depth: Between 400 mm (16”) and 900 mm (36”).<br />

5.3.6 SLAB DESIGN<br />

The minimum slab thickness is 70 mm (2 3 /4”) and the slab<br />

capacity chart tables 8 and 9 on page 19 and 20 shows the<br />

total allowable load (including the dead load of the slab)<br />

based on 20 MPa (3 000 psi) concrete.<br />

5.3.7 ROLLBAR<br />

Standard 1 251 mm (4’-1 1 /4”) roll bars are used to support<br />

the plywood forms.<br />

5.3.8 FORMS<br />

Regular 1 220 mm (4’-0”) plywood forms must be slit in<br />

half, 610 mm x 2 440 mm (2’ x 8’) panels, to allow insertion<br />

between the top chords. Normally 12.7 mm ( 1 /2”) plywood<br />

is used.<br />

5.3.9 INSTALLATION<br />

Installation shall be in accordance with the manufacturer’s<br />

recommendations. Particular attention should be paid to<br />

the erection of the long span <strong>Hambro</strong> joists and bridging<br />

must be installed as specified on the <strong>Hambro</strong> drawing.<br />

5.3.10 TYPICAL DETAILS<br />

See typical details section page 23 to 27.<br />

610 mm VAR<br />

2<br />

610 mm 610 mm<br />

24” 24” 24”<br />

Variable panel P<br />

d = Joist depth<br />

P1 = d + 300 mm (12”) ≤ 1 170 mm (46”)<br />

VAR 1 = 0 to 150 mm (6”)<br />

VAR 2 = 150 mm (6”) to 610 mm (24”)<br />

“n” Continuous panels<br />

d<br />

3