SECTION 10 - MAXIMUM LH DUCT OPENINGS TABLES<br />
SECTION 9 - FLANGE HANGER FOR INSULATED CONCRETE FORM<br />
26<br />
DEPTH PANEL D S R<br />
(mm) (mm) (mm) (mm) (mm x mm)<br />
610 610 415 335 455 x 275<br />
560 x 225<br />
660 610 445 360 455 x 305<br />
560 x 250<br />
711 610 475 380 460 x 335<br />
610 x 245<br />
762 610 500 400 560 x 300<br />
685 x 220<br />
813 610 525 420 560 x 325<br />
685 x 240<br />
864 610 545 435 560 x 350<br />
735 x 225<br />
914 610 565 455 610 x 335<br />
735 x 240<br />
965 610 585 470 610 x 360<br />
735 x 260<br />
20 mm ( 3/4”)Ø HOLES<br />
AT 600 mm (24”) c /c<br />
FOR ANCHORED<br />
TYPICAL DETAILS<br />
FLANGE HANGER<br />
(TYPE M.H)<br />
ROLLBAR<br />
REINFORCED INSULATED CONCRETE WALL<br />
DEPTH PANEL D S R<br />
(in.) (in.) (in.) (in.) (in. x in.)<br />
24 24 16 1/2 13 1/4 18 x 10 3/4<br />
22 x 8 3/4<br />
26 24 17 1/2 14 18 x 12<br />
22 x 9 3/4<br />
28 24 18 3/4 15 18 x 13 1/4<br />
24 x 9 3/4<br />
30 24 19 3/4 15 3/4 22 x 11 3/4<br />
27 x 8 3/4<br />
32 24 20 1/2 16 1/2 22 x 12 3/4<br />
27 x 9 1/2<br />
34 24 21 1/2 17 1/4 22 x 13 3/4<br />
29 x 8 3/4<br />
36 24 22 1/4 18 24 x 13 1/4<br />
29 x 9 1/2<br />
38 24 23 18 1/2 24 x 14 1/4<br />
29 x 10 1/4<br />
SECTION 10 - MAXIMUM DUCT OPENINGS (LH)<br />
** WEB OPENINGS ARE ALIGNED ONLY WITH JOISTS WHICH HAVE IDENTICAL LENGTHS **<br />
PANEL PANEL PANEL PANEL<br />
TOP OF SLAB<br />
S<br />
D<br />
R<br />
JOIST DEPTH<br />
NOMINAL<br />
S = MAXIMUM SQUARE<br />
R = MAXIMUM RECTANGLE<br />
D = MAXIMUM DIAMETER<br />
NOTE: The maximum limitation has been determined from the joist geometry,<br />
with a bottom chord of 50 mm (2”) and web of 35 mm (1 3/8”). If more<br />
information needed, please contact the <strong>Hambro</strong> technical department.