SECTION 11 - JOIST PARALLEL TO A CONCRETE WALL<br />

WITH INSULATED FORM<br />

REBAR<br />

(IF REQUIRED BY THE<br />

CONSULTING ENGINEER)<br />

WELDED WIRE-MESH<br />

(T)<br />

SLAB<br />

FLANGE HANGER<br />

(FIXED, SEE ED-D500)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

TYPICAL DETAILS<br />

REINFORCED INSULATED CONCRETE WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

SECTION 12 - JOIST BEARING ON CONCRETE WALL<br />

WITH INSULATED FORM<br />

90 mm (3 1 /2”) MIN. FOR 100 mm (4”) SHOE (TYP.)<br />

NO ANCHORED PLATE OR MECHANICAL<br />

FASTENER IS REQUIRED TO FIX<br />

THE JOIST TO THE CONCRETE WALL.<br />

NOTCH RIGID INSULATION (TYP.)<br />

WELDED WIRE-MESH<br />

SLAB<br />

(T)<br />

T + 35 mm (1<br />

TOP OF BEARING<br />

3/8”)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

CEILING EXTENSION<br />

CEILING EXTENSION<br />

REINFORCED INSULATED CONCRETE WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

REBAR<br />

(IF REQUIRED BY THE<br />

CONSULTING ENGINEER)<br />