SECTION 28 - CANTILEVERED BALCONY (SHALLOW JOIST PARALLEL TO BALCONY)<br />

SEE PLAN<br />

SEE PLAN<br />

SEE SPECIFICATIONS<br />

OF THE ARCHITECT<br />

TOTAL SLAB (S)<br />

NOMINAL<br />

SLAB (T)<br />

THICKER SLAB<br />

(TS)<br />

50 mm (2”) MIN.<br />

TYP.<br />

WELDED<br />

WIRE-MESH<br />

25 mm (1”)<br />

REBAR,<br />

ACCORDING ACCORDING TO TO THE<br />

THE<br />

SPECIFICATIONS SPECIFICATIONS OF THE<br />

CONSULTING ENGINEER ENGINEER ENGINEER<br />

SLOPE<br />

NOMINAL<br />

JOIST<br />

DEPTH (D)<br />

STEEL DECK<br />

TYPICAL DETAILS<br />

SOLID MASONRY WALL,<br />

ACCORDING TO THE<br />

SPECIFICATIONS OF THE<br />

CONSULTING ENGINEER<br />

BRIDGING TO BOTTOM CHORD MAY<br />

BE NECESSARY IF UPLIFT DUE TO<br />

CANTILEVER BALCONY EXCEEDS<br />

GRAVITY LOAD. (IF REQUIRED BY<br />

THE ENGINEER)<br />

TEMPORARY<br />

SUPPORT<br />

FOR BALCONY<br />

(DESIGNED &<br />

SUPPLIED BY OTHERS)<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING ENGINEER)<br />

S + TS<br />

TOP OF BEARING<br />

IMPORTANT;<br />

BRIDGING ANGLES TO BE INSTALLED AFTER FORMS STRIPPED BUT<br />

BEFORE THE REMOVAL OF BALCONY TEMPORARY SUPPORTS<br />

SECTION 29 - CANTILEVERED BALCONY (JOIST PARALLEL TO BALCONY)<br />

SEE PLAN<br />

SEE PLAN<br />

SEE SPECIFICATIONS<br />

OF THE ARCHITECT<br />

TOTAL SLAB (S)<br />

NOMINAL<br />

SLAB (T)<br />

THICKER SLAB<br />

(TS)<br />

WELDED<br />

WIRE-MESH<br />

50 mm (2”) MIN.<br />

TYP.<br />

REBAR,<br />

ACCORDING TO TO TO THE<br />

THE<br />

SPECIFICATIONS OF THE THE THE<br />

CONSULTING ENGINEER<br />

ENGINEER<br />

25 mm (1”)<br />

SLOPE<br />

NOMINAL<br />

JOIST<br />

DEPTH (D)<br />

ANGLE FOR<br />

THICKER SLAB<br />

BRIDGING TO BOTTOM CHORD MAY<br />

BE NECESSARY IF UPLIFT DUE TO<br />

CANTILEVER BALCONY EXCEEDS<br />

GRAVITY LOAD. (IF REQUIRED BY<br />

THE ENGINEER)<br />

STEEL DECK<br />

TEMPORARY<br />

SUPPORT<br />

FOR BALCONY<br />

(DESIGNED &<br />

SUPPLIED BY OTHERS)<br />

S + TS<br />

TOP OF BEARING<br />

SOLID MASONRY WALL, ACCORDING<br />

TO THE SPECIFICATIONS OF THE<br />

CONSULTING ENGINEER<br />

REBAR<br />

(IF REQUIRED BY THE<br />

CONSULTING ENGINEER)<br />

IMPORTANT;<br />

BRIDGING ANGLES TO BE INSTALLED AFTER FORMS STRIPPED BUT<br />

BEFORE THE REMOVAL OF BALCONY TEMPORARY SUPPORTS<br />