SECTION 19 - JOIST PARALLEL TO EXPANSION JOINT<br />

SECTION 17 - EXPANSION JOINT AT ROOF (AT STEEL BEAM)<br />

18<br />

65 mm (2 1 /2”) MIN. FOR 75 mm (3”)<br />

OR FOR 100 mm (4”) SHOE (TYP.)<br />

40 mm (1 1 /2”)<br />

5 mm ( 3/16”)<br />

NOMINAL<br />

SLAB (T)<br />

TOTAL<br />

SLAB<br />

FIBRE BOARD 12 mm ( 1 75 mm (3”) MIN.<br />

DO NOT WELD THE STEEL DECK<br />

TYP.<br />

ON THE EMBEDED MATERIAL<br />

/2”) WELDED WIRE-MESH<br />

FIBRE BOARD 12 mm ( 1 /2”)<br />

12 mm ( 1 /2”)Ø ROD x 600 mm (24”)<br />

@ 600 mm (24”) c /c<br />

GREASE OR WRAP THIS END<br />

OF ROD WITH BUILDING PAPER<br />

NOMINAL<br />

SLAB<br />

(T)<br />

DO NOT WELD THE<br />

SHOE ON THE BEAM<br />

STEEL DECK<br />

WELDED WIRE-MESH<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

STEEL DECK<br />

TOTAL<br />

SLAB<br />

SOLID MASONRY WALL,<br />

ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

T + 38 mm (1 1 /2”)<br />

TOP OF BEARING<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

T + 38 (1 1 /2”)<br />

TOP OF BEARING<br />

TYPICAL DETAILS<br />

REBAR<br />

(IF REQUIRED BY<br />

THE CONSULTING ENGINEER)<br />

CEILING EXTENSION<br />

CEILING EXTENSION<br />

STEEL BEAM ACCORDING TO<br />

THE SPECIFICATIONS OF THE<br />

CONSULTING ENGINEER (UNO)<br />

SECTION 20 - JOIST PARALLEL TO A MASONRY WALL<br />

OR CONCRETE WALL<br />

SECTION 18 - MINIMUM CLEARANCE FOR OPENING<br />

AND HOLE IN THE SLAB<br />

STEEL DECK ANCHORED<br />

TO THE WALL<br />

WELDED WIRE-MESH<br />

50 mm (2”) MIN.<br />

TYP.<br />

NOMINAL<br />

SLAB (T)<br />

TOTAL<br />

SLAB<br />

DIAMETER � 200 mm (8”)<br />

** REBAR AROUND THE<br />

HOLE IS NOT REQUIRED<br />

** THE QUANTITY OF HOLE<br />

AT 150 mm (6”) & MORE<br />

OF THE JOIST IS<br />

NOT IMPORTANT<br />

150 mm (6”)<br />

MIN.<br />

150 mm (6”)<br />

MIN.<br />

OPENING<br />

SEE TYPICAL<br />

REINFORCEMENT<br />

FOR SLAB OPENING.<br />

150 mm (6”)<br />

MIN.<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

STEEL DECK<br />

SOLID MASONRY WALL OR REINFORCED CONCRETE<br />

WALL, ACCORDING TO THE SPECIFICATIONS<br />

OF THE CONSULTING ENGINEER<br />

T + 38 mm (1 1 /2”)<br />

TOP OF BEARING<br />

NOMINAL<br />

SLAB<br />

(T)<br />

20 mm ( 3 /4”) MIN.<br />

APPLICABLE<br />

IN EACH CASE<br />

20 mm ( 3 /4”) MIN.<br />

APPLICABLE<br />

IN EACH CASE<br />

END OF<br />

SLAB<br />

TOTAL<br />

SLAB<br />

HOLE<br />

REBAR<br />

(IF REQUIRED BY THE<br />

CONSULTING ENGINEER)<br />

NOMINAL<br />

JOIST DEPTH<br />

(D)<br />

STEEL DECK<br />

WELDED WIRE-MESH<br />

TEMPORARY<br />

SUPPORT<br />

(DESIGNED<br />

& SUPPLIED<br />

BY OTHERS)