27.08.2015 Views

Carriers

Plastic Cable Carriers

Plastic Cable Carriers

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical Data — M Series<br />

Type MC 1250<br />

Divider systems<br />

for stay variant “RM“<br />

Divider system TS 0<br />

without height subdivision<br />

The divider system can be planned by you or by our engineers on the<br />

basis of the information you supply about the configuration of the<br />

cable carrier.<br />

As standard, the divider system is fitted on every frame stay!<br />

(with stay assembly on every 2nd chain link)<br />

s T = 5 mm<br />

a T min = 10 mm<br />

a x min = 20 mm<br />

69<br />

69<br />

Please state the number of<br />

dividers/cross section n T when ordering.<br />

s T<br />

Sample order:<br />

Divider system TS 0/n T 3<br />

a TL<br />

a X<br />

B i<br />

a TR<br />

The dividers can slide along the chain cross section!<br />

Divider system TS 5<br />

Hole stay – split design<br />

B<br />

Calculation of Bi<br />

B i = Σ n p B p - 3 mm<br />

n p = Number of hole stay inserts<br />

B p = Width of hole stay inserts<br />

D<br />

69<br />

96<br />

99.5<br />

KR<br />

Calculation of chain width:<br />

B k = B i + 45 mm<br />

Calculation of chain width over<br />

universal connector:<br />

B EF = B i + 51 mm<br />

Please state the hole diameter and position<br />

(from left to right) when placing your<br />

order.<br />

Sample order: Divider System TS 5<br />

B 1 = 50 mm, B 2 = 30 mm, B 3 = 25 mm,<br />

B 4 = 45 mm<br />

If possible please enclose a sketch.<br />

Size Width<br />

D<br />

B<br />

10 15<br />

15 20<br />

20 25<br />

25 30<br />

30 35<br />

40 45<br />

50 55<br />

55 60<br />

(B i )<br />

B k<br />

B EF<br />

Glide shoes can be attached<br />

for long travel lengths<br />

KR min = 180 mm<br />

22.5<br />

D<br />

B<br />

The hole stay inserts can be combined according to preference.<br />

The cables and hoses must be able to move freely in the cable carrier.<br />

In order to calculate the required free space the following values apply:<br />

for round cables:<br />

10 % of the cable diameter<br />

for hoses:<br />

20 % of the hose diameter<br />

3.434 Subject to technical changes! MC

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!