Technical Data — M Series<br />

Type ME/MK 1250<br />

Divider systems<br />

for Stay variant “RE and RD“<br />

The divider system can be planned by<br />

you or by our engineers on the basis of<br />

the information you supply about the<br />

configuration of the cable carrier.<br />

As standard the stay system is fitted to<br />

every frame stay (with stay assembly on<br />

every 2nd chain link).<br />

Version A<br />

Notch in connecting<br />

profile to the<br />

inside<br />

(Standard)<br />

The dividers can<br />

slide along the<br />

section.<br />

Version B<br />

Notch in connecting<br />

profile to the<br />

outside<br />

The dividers are<br />

fixed in the section<br />

(a x -grid 16 mm)<br />

Divider system TS 0<br />

without height subdivision<br />

Dividers can slide along the cross-section (Version A) or are fixed<br />

(Version B). For divider version B please state fitting intervals<br />

a T and a x !<br />

Version A Version B<br />

s T 8 mm 8 mm<br />

a T min 5 mm 19.5 mm<br />

a x min 14.5 mm 16 mm<br />

a x grid continuous 16 mm<br />

72<br />

Please state the type and the number of<br />

dividers/cross section n T when ordering.<br />

Sample order:<br />

Divider system TS 0-A / n T 4<br />

s T<br />

a TL a x1<br />

a TR<br />

B i<br />

KR<br />

VR 1 VR 4 VR 5 VR 45 VR 145<br />

34 34<br />

18<br />

50<br />

50<br />

18<br />

18<br />

28<br />

18<br />

18 12 12 18<br />

6<br />

4<br />

2<br />

1<br />

3<br />

5<br />

7<br />

32<br />

KR<br />

Divider system TS 1<br />

with continuous height subdivision<br />

Height subdivision: Al-Profile 11 x 4 mm<br />

Technically recommended variants: VD 1, VD 4, und VD 5<br />

Dividers can slide along the cross-section (Version A) or are fixed<br />

(Version B). For divider version B please state fitting intervals<br />

a T and a x !<br />

s T<br />

a TL a x1<br />

a x2<br />

a TR<br />

B i<br />

Position of the<br />

subdivision(s)<br />

in the divider<br />

Version A Version B<br />

s T 8 mm 8 mm<br />

a T min 5 mm 19.5 mm<br />

a x min 14.5 mm 16 mm<br />

a x grid continuous 16 mm<br />

n T min 2 2<br />

Please state the type of height subdivisions and the number of<br />

dividers/cross section n T when ordering.<br />

Sample order: Divider system TS 1– VD 45/n T 5<br />