Design Guidelines<br />

Vertical arrangement - hanging<br />

Pre-tension<br />

No or only the minimum pre-tension should be applied to the<br />

cable carrier.<br />

If we know the installation variant, for vertical “hanging” arrangements<br />

KABELSCHLEPP will only supply cable carriers without pretension!<br />

Connections<br />

Extreme care should be taken when fixing the cable carrier to the<br />

driver and to the fixed point.<br />

It may be that a short support device will need to be provided!<br />

Installation of cables / hoses<br />

Also with this arrangement the proper installation of all electric<br />

cables and hoses is very important.<br />

Please ensure that:<br />

All cables / hoses are installed in such a way that they can move<br />

freely in the cable carrier, ie the weight of the cables / hoses<br />

should not place an additional strain on the cable carrier.<br />

The cable carrier has a protective and guiding function!<br />

In order to guarantee this, extreme care should be taken when<br />

hanging / fixing the cables / hoses to the driver and to the fixed<br />

point.<br />

Please be sure to take into account the fact that hanging electric<br />

cables and hoses “extend” after a certain amount of time and will<br />

therefore need to be readjusted.<br />

The cables / hoses must be installed clearly separated from one<br />

another in the cross-section of the cable carrier.<br />

We recommend the use of frame stays with a divider system<br />

or of KABELSCHLEPP hole stays.<br />

With this design the last two stays (at the driver and at<br />

the fixed point) can be designed as clamping stays, thus<br />

guaranteeing optimum strain relief.<br />

Note:<br />

Randomly / incorrectly installed cables / hoses often soon become<br />

damaged because of the continuous relative movement (of the<br />

cables between themselves).<br />

Flexible control cables with small cross-sections are<br />

especially at risk!<br />

Owing to the multitude of design options which need to be<br />

considered, we would ask that you consult our design team.<br />

We will be delighted to advise you!<br />

Many installations of this kind have been delivered world-wide,<br />

whereby travel lengths in excess of 50 m have been realised using<br />

plastic and steel cable carriers.<br />

We reserve the right to make technical changes! 2.23