09.10.2015 Views

OS-C501

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Offshore Standard DNV-<strong>OS</strong>-<strong>C501</strong>, November 2013<br />

App.E Tables of safety factors – Page 229<br />

Table E-14 Target reliability level D<br />

Distribution types Local response: Weibull Characteristic load: 99% quantile<br />

Resistance: Normal<br />

Characteristic resistance: 2.5% quantile<br />

Local response<br />

Resistance COV<br />

COV<br />

0.00 0.05 0.10 0.125 0.15<br />

0.00 γ FM<br />

1.18<br />

1.53<br />

1.86<br />

2.46<br />

γ FM = γ F x γ M 1.00x1.18 1.00x1.53 1.00x1.86 1.00x2.46<br />

0.05 1.05<br />

1.05x1.00<br />

1.14<br />

0.99x1.16<br />

1.45<br />

0.96x1.51<br />

1.75<br />

0.95x1.84<br />

2.30<br />

0.94x2.44<br />

0.10 1.09<br />

1.14<br />

1.40<br />

1.67<br />

2.17<br />

1.09x1.00 1.02x1.12 0.96x1.47 0.93x1.80 0.91x2.40<br />

0.15 1.15<br />

1.15x1.00<br />

1.16<br />

1.07x1.09<br />

1.38<br />

0.97x1.42<br />

1.62<br />

0.93x1.74<br />

2.08<br />

0.89x2.33<br />

0.20 1.21<br />

1.21x1.00<br />

1.19<br />

1.13x1.06<br />

1.37<br />

1.01x1.37<br />

1.59<br />

0.95x1.68<br />

2.00<br />

0.89x2.26<br />