Offshore Standard DNV-<strong>OS</strong>-<strong>C501</strong>, November 2013<br />

App.H Example for representative data – Unidirectional carbon tapes made of TPW tape with “5631” fibres – Page 244<br />

Table H-1 Properties to define the material (Continued)<br />

A B C D<br />

Requirements to group measurements from different laminates<br />

Constituent materials: Tenax STS 5631 Tenax HTS 5631 Tenax HTS 5631 Tenax UTS 5631<br />

1600tex<br />

800tex<br />

1600tex<br />

800tex<br />

f24000 t0 f12000 t0 f24000 t0<br />

f12000 t0<br />

Processing method Autoclave cured Autoclave cured Autoclave cured Autoclave cured<br />

Processing temperature 140°C for 60 180°C for 20 180°C for 20 minutes 180°C for 20 minutes<br />

minutes<br />

minutes<br />

Processing pressure 4.0 bar 5.0 bar 5.0 bar 5.0 bar<br />

Process atmosphere (e.g. 0.99 bar 0.99 bar 0.99 bar 0.99 bar<br />

vacuum)<br />

Post curing (temperature none None none none<br />

and time)<br />

Control of fibre orientation --- --- --- ---<br />

Fibre volume fraction 58-60% 54.5-57.8% 54.5-57.8% 54.6-60%<br />

Void content 1.88 - 2.06% 0.79% 0.69% 1.3%<br />

Conditioning parameters:<br />

See sections for properties:<br />

H.3 Quasi static properties in air (QSA)<br />

H.3.1 Test environment<br />

H.3.1.1 The test environment is described according to Sec.4 [8.5.2].<br />

H.3.1.2 The following properties are listed according to Sec.4 [2.2]. Characteristic values are calculated<br />

according to Sec.4 [2.4].<br />

H.3.1.3 Data are based on a set of 6 measurements for each property, backed up by more than 50 measurements<br />

from production control.<br />

Table H-2 Conditioning parameters<br />

Temperature 23 °C<br />

Water content of the laminate (wet, dry)<br />

Dry<br />

Chemical environment<br />

Air<br />

Loading rate 1-2 mm / minute *<br />

number of specimens<br />

Reported individually for all properties<br />

* Rates varied slightly between test methods. Shear data were obtained from ±45 laminates tested at 2 mm/minute and sometimes at<br />

faster rates of about 6 mm/min after 2% strain.<br />

DET NORSKE VERITAS AS