Configuring Virtual Chassis<br />

Configuring Virtual Chassis<br />

-> virtual-chassis hello-interval 10<br />

Configuring the Control VLAN<br />

Under normal circumstances, it is not necessary to change the control VLAN.<br />

However, it is important to note that the VLAN configured as the Control VLAN is reserved specifically<br />

for transferring virtual chassis control information purposes and it can no longer be used for normal data<br />

traffic.<br />

If necessary, use the virtual-chassis configured-control-vlan command to modify the Control VLAN.<br />

For example:<br />

-> virtual-chassis configured-control-vlan 4093<br />

Configuring Virtual Chassis EMP IP Addresses<br />

In order to access the virtual chassis through the EMP IP addresses the port's IP address and network mask<br />

can be configured. There are multiple IP addresses to consider when configuring the EMP IP addresses in<br />

a virtual chassis environment.<br />

• The Virtual Chassis EMP IP address represents the address of the entire virtual chassis (EMP-VC).<br />

This address is automatically assigned to the Master chassis and can be used for remote access to the<br />

entire Virtual Chassis.<br />

• The Chassis EMP IP address is assigned to each switch comprising the virtual chassis (i.e. EMP-<br />

CHAS1, EMP-CHAS2, EMP-CHAS3, etc.). This address can be used for remote access to each switch<br />

comprising the virtual chassis. This address is automatically assigned to the local chassis.<br />

• All the EMP IP addresses and CMM’s IP addresses must be in the same subnet.<br />

• Each of the IP addresses must be unique.<br />

Note: The Virtual Chassis EMP addresses are only supported on OS680E models (non-E models do not<br />

have an EMP port). When configuring VC EMP addresses in a VC with a mix of <strong>OS6860</strong>E models and<br />

<strong>OS6860</strong>-non-E models the VC could become unreachable via the EMP port if a non-E model becomes<br />

Master. In a mixed VC environment it's recommended to create a management VLAN for remote management<br />

purposes.<br />

Configuring the Chassis EMP IP Address<br />

Use the ip interface command to modify the Chassis EMP IP address as shown below. These commands<br />

would be issued after the virtual chassis is operational:<br />

-> ip interface local chassis-id 1 emp address 10.255.100.1 mask 255.255.255.0<br />

-> ip interface local chassis-id 2 emp address 10.255.100.2 mask 255.255.255.0<br />

Configuring the Virtual Chassis EMP IP Address<br />

Use the ip interface command to modify the Virtual Chassis EMP IP address as shown below. These<br />

commands would be issued after the virtual chassis is operational:<br />

-> ip interface master emp address 10.255.100.100 mask 255.255.255.0<br />