29.04.2019 Views

OS6860(E)_AOS_8.1.1.R01_Switch_Management_Guide

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SNMP Traps Table<br />

No. Trap Name Objects Family Description<br />

alaSvcId—The unique Service identifier.<br />

alaSdpBindId—The SDP Binding identifier.<br />

alaSdpBindOperStatus—The SDP Binding status:<br />

• up<br />

• noEgressLabel<br />

• noIngressLabel<br />

• noLabels<br />

• down<br />

• svcMtuMismatch<br />

• sdpPathMtuTooSmall<br />

• sdpNotReady<br />

• sdpDown<br />

• sapDown<br />

• created - dynamically created for SPB<br />

• destroyed - dynamically destroyed for SPB<br />

alaSdpBindNetworkPort—The network port associated with a service instance where MPLS labeled or B-<br />

Domain packets ingress and egress.<br />

alaSdpBindBVlan—The Backbone VLAN ID (BVLAN) associated with the SDP Binding object.<br />

alaSdpBindSystemId—The neighbor Backbone MAC (B-MAC) associated with the SDP Binding object.<br />

alaSdpBindSystemName,—The neighbor host name associated with the SDP Binding object.<br />

alaSdpBindIsid—The I-Domain Service Indentifier (I-SID) for the Group MAC assigned to this Multicast<br />

SDP Bind.<br />

171 alaPethPwrSupplyConflictTrap pethPsePort-<br />

GroupIndex<br />

pethPsePortGroupIndex—The slot of the involved object.<br />

module<br />

This trap is sent when there is a<br />

power supply type conflict.<br />

172 alaPethPwrSupplyNotSupported module This trap is sent when the power<br />

supply is not supported.<br />

pethPsePortGroupIndex—The slot of the involved object.<br />

pethPsePortIndex—The port of the involved object.<br />

173 chasTrapsBPSLessAllocSysPwr physicalIndex,<br />

chasTraps Ni<br />

RqstdBps<br />

SysPower,<br />

chasTrapsNi-<br />

GrantdBps<br />

SysPower<br />

chassis<br />

physicalIndex—The physical index of the involved object.<br />

chasTrapsNiRqstdBpsSysPower—The requested system power from OS-BPS.<br />

chasTrapsNiGrantdBpsSysPower—The granted system power from OS-BPS.<br />

174 chasTrapsBPSStateChange chasTrapBPSShelfId,<br />

chasTrapsBP-<br />

SPowerSupply,<br />

chasTrapsBP-<br />

SEventAlert<br />

chassis<br />

chasTrapBPSShelfId—The BPS Shelf identifier.<br />

chasTrapsBPSPowerSupply—The BPS Power Supply involced in the trap.<br />

chasTrapsBPSEventAlert—An enumerated value identifying alert.<br />

This trap is sent when there is<br />

insufficient system power provided<br />

by the BPS.<br />

This trap is sent when BPS<br />

Power Supplies are inserted or<br />

removed.<br />

Omni<strong>Switch</strong> <strong>AOS</strong> Release 8 <strong>Switch</strong> <strong>Management</strong> <strong>Guide</strong> May 2014 page B-43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!