29.04.2019 Views

OS6860(E)_AOS_8.1.1.R01_Switch_Management_Guide

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SNMP Traps Table<br />

No. Trap Name Objects Family Description<br />

175 chasTrapsNiBPSFETStateChange physicalIndex,<br />

chasTrapsB-<br />

PSSystem-<br />

FETChange,<br />

chasTrapsBPS-<br />

PoeFETChan<br />

ge<br />

chassis<br />

physicalIndex—The physical index of the involved object.<br />

chasTrapsBPSSystemFETChange—An enumerated value indicating the BPS FET state.<br />

chasTrapsBPSPoeFETChange—An enumerated value indicating the PoE FET state.<br />

176 alaDhcpBindingDuplicateEntry dhcpSnooping-<br />

Binding-<br />

MacAddress,<br />

dhcpSnooping-<br />

BindingVlan,<br />

dhcpSnooping-<br />

BindingIfIndex,<br />

ip-helper<br />

This trap is sent when there is a<br />

BPS FET change of state.<br />

This trap is sent when there is a<br />

MAC movement in the DHCP-<br />

Binding Table.<br />

dhcpSnoopingBindingMacAddress—The MAC Address sub-index identifying this instance.<br />

dhcpSnoopingBindingVlan—The DHCP client VLAN.<br />

dhcpSnoopingBindingIfIndex—The the interface from which the DHCP request is coming.<br />

177 alaVCSPProtectionTrap alaVCSPTable-<br />

ChassisID<br />

alaVCSPTableChassisID—The virtual chassis ID (1 - 8).<br />

178 alaVCSPRecoveryTrap alaVCSPTable-<br />

ChassisID<br />

vcm<br />

vcm<br />

This trap is sent when a virtual<br />

chassis enters into VCSP Protection<br />

state<br />

This trap is sent when a virtual<br />

chassis enters into VCSP Active<br />

state<br />

alaVCSPTableChassisID—The virtual chassis ID (1 - 8).<br />

179 pethPsePortOnOffNotification NA module This trap is sent to indicate<br />

whether or not the PSE Port is<br />

delivering power to the PD. This<br />

notification SHOULD be sent on<br />

every status change except in the<br />

searching mode.<br />

NA<br />

180 pethMainPowerUsageOnNotification NA module This trap is sent to indicate that<br />

the PSE Threshold usage indication<br />

is on, the usage power is<br />

above the threshold. At least 500<br />

msec must elapse between notifications<br />

being emitted by the<br />

same object instance.<br />

NA<br />