Brugsvejledning Directions for use Bedienungsanweisung ... - Velux

velux.dk
  • No tags were found...

Brugsvejledning Directions for use Bedienungsanweisung ... - Velux

Allocation of clamps1.3.5 Allocation of clamps for system 52-store-solar system with valve logic with 2 stores,3 sensors, 1 solar pump and 1 3-way-valve. The sensorS4/TRF can optionally be used for heat quantitybalancing.ARR 5SymbolSpecificationS1Collector sensorS2 Store sensor 1S1S3 Store sensor 2R2S4/TRFSensor for heatquantity balancing(optionally)R1Store 1 Store 2R1R2Solar pump3-way-valveS4/TRFS2S31.3.6 Allocation of clamps for system 62-store-solar system with pump logic with 2 stores,3 sensors and 2 solar pumps. The sensor S4/TRF canoptionally be used for heat quantity balancing.ARR 6SymbolSpecificationS1Collector sensorS2 Store sensor 1S1S3 Store sensor 2S4/TRFMeasuring sensor(optionally)S4/TRFStore 1 Store 2R1 Solar pump 1R2 Solar pump 2R1R2S2S339 VELUX