Table 8: Extended Temperature Operation (Sheet 2 of 2)<br />
Symbol Parameter 1<br />
Min Nom Max Unit Notes<br />
Block<br />
Erase<br />
Cycles<br />
Main and Parameter Blocks<br />
Main Blocks<br />
Parameter Blocks<br />
VPP < VCC VPP = 12 V<br />
VPP = 12 V<br />
100,000<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
1000<br />
2500<br />
Cycles 2<br />
2<br />
Notes:<br />
1. See Section 6.1, “DC Current Characteristics” on page 26 and Section 6.2, “DC Voltage<br />
Characteristics” on page 27 for specific voltage-range specifications.<br />
2. VPP is normally VPPL . VPP can be connected to 11.4 V–12.6 V for 1000 cycles on main blocks for extended<br />
temperatures and 2500 cycles on parameter blocks at extended temperature.<br />
3.<br />
4.<br />
Contact your Numonyx field representative for VCC /VCCQ operations down to 1.65 V.<br />
See the tables in Section 6.0, “Electrical Specifications” on page 26 and in Section 7.0,<br />
“AC Characteristics” on page 28 for operating characteristics<br />