You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Numonyx <strong>Wireless</strong> <strong>Flash</strong> <strong>Memory</strong> (<strong>W30</strong>)<br />
7.4 Erase and Program Times<br />
Table 14: Erase and Program Times<br />
Operation Symbol Parameter Description1 Notes<br />
Erasing and Suspending<br />
Erase Time<br />
Suspend<br />
Latency<br />
Programming<br />
November 2007 Datasheet<br />
Order Number: 290702-13 43<br />
V PPL<br />
V PPH<br />
Typ Max Typ Max<br />
W500 tERS/PB 4-Kword Parameter Block 2,3 0.3 2.5 0.25 2.5 s<br />
W501 tERS/MB 32-Kword Main Block 2,3 0.7 4 0.4 4 s<br />
W600 tSUSP/P Program Suspend 2 5 10 5 10 µs<br />
W601 tSUSP/E Erase Suspend 2 5 20 5 20 µs<br />
W200 tPROG/W Single Word 2 12 150 8 130 µs<br />
Program<br />
Time<br />
W201 tPROG/PB 4-Kword Parameter Block 2,3 0.05 .23 0.03 0.07 s<br />
W202 tPROG/MB 32-Kword Main Block 2,3 0.4 1.8 0.24 0.6 s<br />
Enhanced Factory Programming5<br />
Program<br />
Operation<br />
Latency<br />
W400 tEFP/W Single Word 4 N/A N/A 3.5 16 µs<br />
W401 tEFP/PB 4-Kword Parameter Block 2,3 N/A N/A 15 - ms<br />
W402 tEFP/MB 32-Kword Main Block 2,3 N/A N/A 120 - ms<br />
W403 tEFP/SETUP EFP Setup - N/A N/A - 5 µs<br />
W404 tEFP/TRAN Program to Verify Transition - N/A N/A 2.7 5.6 µs<br />
W405 tEFP/VERIFY Verify - N/A N/A 1.7 130 µs<br />
Notes:<br />
1. Unless noted otherwise, all parameters are measured at T A = +25 °C and nominal voltages, and are sampled, not 100%<br />
tested.<br />
2. Excludes external system-level overhead.<br />
3. Exact results might vary based on system overhead.<br />
4. W400-Typ is the calculated delay for a single programming pulse. W400-Max includes the delay when programming<br />
within a new word-line.<br />
5. Some EFP performance degradation might occur if block cycling exceeds 10.<br />
Unit