21.02.2013 Views

Numonyxâ„¢ Wireless Flash Memory (W30)

Numonyxâ„¢ Wireless Flash Memory (W30)

Numonyxâ„¢ Wireless Flash Memory (W30)

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Numonyx <strong>Wireless</strong> <strong>Flash</strong> <strong>Memory</strong> (<strong>W30</strong>)<br />

7.4 Erase and Program Times<br />

Table 14: Erase and Program Times<br />

Operation Symbol Parameter Description1 Notes<br />

Erasing and Suspending<br />

Erase Time<br />

Suspend<br />

Latency<br />

Programming<br />

November 2007 Datasheet<br />

Order Number: 290702-13 43<br />

V PPL<br />

V PPH<br />

Typ Max Typ Max<br />

W500 tERS/PB 4-Kword Parameter Block 2,3 0.3 2.5 0.25 2.5 s<br />

W501 tERS/MB 32-Kword Main Block 2,3 0.7 4 0.4 4 s<br />

W600 tSUSP/P Program Suspend 2 5 10 5 10 µs<br />

W601 tSUSP/E Erase Suspend 2 5 20 5 20 µs<br />

W200 tPROG/W Single Word 2 12 150 8 130 µs<br />

Program<br />

Time<br />

W201 tPROG/PB 4-Kword Parameter Block 2,3 0.05 .23 0.03 0.07 s<br />

W202 tPROG/MB 32-Kword Main Block 2,3 0.4 1.8 0.24 0.6 s<br />

Enhanced Factory Programming5<br />

Program<br />

Operation<br />

Latency<br />

W400 tEFP/W Single Word 4 N/A N/A 3.5 16 µs<br />

W401 tEFP/PB 4-Kword Parameter Block 2,3 N/A N/A 15 - ms<br />

W402 tEFP/MB 32-Kword Main Block 2,3 N/A N/A 120 - ms<br />

W403 tEFP/SETUP EFP Setup - N/A N/A - 5 µs<br />

W404 tEFP/TRAN Program to Verify Transition - N/A N/A 2.7 5.6 µs<br />

W405 tEFP/VERIFY Verify - N/A N/A 1.7 130 µs<br />

Notes:<br />

1. Unless noted otherwise, all parameters are measured at T A = +25 °C and nominal voltages, and are sampled, not 100%<br />

tested.<br />

2. Excludes external system-level overhead.<br />

3. Exact results might vary based on system overhead.<br />

4. W400-Typ is the calculated delay for a single programming pulse. W400-Max includes the delay when programming<br />

within a new word-line.<br />

5. Some EFP performance degradation might occur if block cycling exceeds 10.<br />

Unit