Numonyx <strong>Wireless</strong> <strong>Flash</strong> <strong>Memory</strong> (<strong>W30</strong>) (<strong>W30</strong>)<br />
After resuming a suspended operation, issue the read command appropriate to the<br />
read operation. To read status after resuming a suspended operation, issue a Read<br />
Status Register command (70h) to return the suspended partition to status mode.<br />
Figure 30: Program Suspend / Resume Flowchart<br />
Start<br />
Write B0h<br />
Any Address<br />
Write 70h<br />
Same Partition<br />
Read Status<br />
Register<br />
SR[7] =<br />
1<br />
SR[2] =<br />
1<br />
Write FFh<br />
Susp Partition<br />
Read Array<br />
Data<br />
Done<br />
Reading<br />
Yes<br />
Write D0h<br />
Any Address<br />
Program<br />
Resumed<br />
Write 70h<br />
Same Partition<br />
0<br />
0<br />
No<br />
PROGRAM SUSPEND / RESUME PROCEDURE<br />
Program<br />
Completed<br />
Write FFh<br />
Pgm'd Partition<br />
Read Array<br />
Data<br />
Bus<br />
Command Comments<br />
Operation<br />
Datasheet November 2007<br />
66 Order Number: 290702-13<br />
Write<br />
Write<br />
Read<br />
Standby<br />
Standby<br />
Write<br />
Read<br />
Write<br />
Program<br />
Suspend<br />
Read<br />
Status<br />
Read<br />
Array<br />
Program<br />
Resume<br />
Data = B0h<br />
Addr = Any address within programming<br />
partition<br />
Data = 70h<br />
Addr = Any address in same partition<br />
Read SRD<br />
Toggle CE# or OE# to update SRD<br />
Addr = Any address in same partition<br />
Check SR[7]<br />
1 = WSM ready<br />
0 = WSM busy<br />
Check SR[2]<br />
1 = Program suspended<br />
0 = Program completed<br />
Data = FFh<br />
Addr = Any device address (except word<br />
being programmed)<br />
Read array data from block other than<br />
the one being programmed<br />
Data = D0h<br />
Addr = any device address<br />
If the suspended partition was placed in Read Array mode:<br />
Write<br />
Read<br />
Status<br />
Return partition to status mode:<br />
Data = 70h<br />
Addr = address within same partition