Table 18: Command Codes and Descriptions (Sheet 2 of 2)<br />
Operation Code<br />
Protection C0h<br />
Configuration<br />
60h<br />
03h<br />
Protection<br />
Program<br />
Setup<br />
Configuration<br />
Setup<br />
Set<br />
Configuration<br />
Register<br />
Numonyx <strong>Wireless</strong> <strong>Flash</strong> <strong>Memory</strong> (<strong>W30</strong>) (<strong>W30</strong>)<br />
This command prepares the CUI for a protection register program operation. The<br />
second cycle latches address and data, and starts the WSM protection register<br />
program or lock algorithm. Toggling CE# or OE# updates the flash device status<br />
register data. To read array data after programming, issue a Read Array<br />
command.<br />
This command prepares the CUI for flash device configuration. If Set<br />
Configuration Register is not the next command, the CUI sets SR[5:4] to indicate<br />
a command sequence error.<br />
If the previous command was Configuration Setup (60h), the CUI latches the<br />
address and writes the data from A[15:0] into the configuration register.<br />
Subsequent read operations access the array data.<br />
Note: Do not use unassigned commands. Numonyx reserves the right to redefine these codes for future functions.<br />
Table 19: Bus Cycle Definitions<br />
Operation Command<br />
Read<br />
Program<br />
and<br />
Erase<br />
Lock<br />
<strong>Flash</strong> Device<br />
Command<br />
Bus<br />
Cycles<br />
First Bus Cycle Second Bus Cycle<br />
Oper Addr 1<br />
Description<br />
Data 2,3<br />
Read Array/Reset > 1 Write PnA FFh Read<br />
Oper Addr 1<br />
Read<br />
Address<br />
Data 2,3<br />
Datasheet November 2007<br />
52 Order Number: 290702-13<br />
Array<br />
Data<br />
Read Identifier > 2 Write PnA 90h Read PBA+IA IC<br />
Read Query > 2 Write PnA 98h Read PBA+QA QD<br />
Read Status Register 2 Write PnA 70h Read PnA SRD<br />
Clear Status Register 1 Write XX 50h<br />
Block Erase 2 Write BA 20h Write BA D0h<br />
Word Program 2 Write WA 40h/10h Write WA WD<br />
EFP >2 Write WA 30h Write WA D0h<br />
Program/Erase Suspend 1 Write XX B0h<br />
Program/Erase Resume 1 Write XX D0h<br />
Lock Block 2 Write BA 60h Write BA 01h<br />
Unlock Block 2 Write BA 60h Write BA D0h<br />
Lock-Down Block 2 Write BA 60h Write BA 2Fh