4.4.2. Indicators<br />
The e-Brick has three LED indicators on the rear panel, “24V” is green when the internal<br />
24V supply is on, “K1” is green when the main contactor in the e-Brick is enabled; the third<br />
LED, “OK”, is green in normal operation but red when a fault occurs.<br />
4.4.3. <strong>System</strong> Emergency stop<br />
The e-Brick can only be enabled if the system emergency stop (E-stop) contacts on the<br />
Press connector [P1] are closed, enabling the internal safety relay. The internal controls<br />
monitor the E-stop status using auxiliary contacts on the safety relay; as a safety measure,<br />
the relay can still disable the supply in the event of a control failure.<br />
Warning! Refer to 5.4 for essential safety information relating to E-stop usage.<br />
4.4.4. Contactor<br />
The 3phase power to the main converter in the e-Brick is switched on using an internal<br />
contactor. By design, the contactor coil can only be energised when the press E-stop is<br />
enabled <strong>and</strong> a second relay is switched on. The second relay is switched on by the<br />
embedded controller <strong>and</strong> is enabled from the HMI screen.<br />
4.4.5. Temperature & cooling<br />
Fan failure detection Generates warning to HMI<br />
Internal temperature warning Generates warning to HMI<br />
Over temperature trip Automatic shutdown of e-Brick<br />
4.4.6. Output protection<br />
Voltage limit Output voltage is limited to a specified maximum<br />
Current limit Output current is limited to specified maximum<br />
Short circuit protection Output circuitry will tolerate an indefinite short circuit<br />
Warning! Under no circumstances should either lamp output terminal be electrically connected<br />
to chassis ground; this will invalidate the e-Brick warranty <strong>and</strong> is likely to result in severe damage<br />
to the e-Brick.<br />