3.5.1. Warning indicators<br />

The e-Brick has three indicator LEDs, one for the internal 24V supply status, a second to show<br />

the main contactor (K1) status, <strong>and</strong> a third to indicate fault status. If the K1 LED fails to light when<br />

the lamp is selected <strong>and</strong> no other fault is present, please refer to <strong>GEW</strong> for service support.<br />

3.5.2. General faults<br />

Water cooling unit (chiller) failure<br />

The cooling unit has failed while the printing machine is running.<br />

• Check chiller MCB <strong>and</strong> reset if necessary<br />

• Ensure that the chiller is switched on<br />

• The chiller may have developed a fault; check the control panel to see if a fault is<br />

reported<br />

• Refer to the chiller <strong>manual</strong> for further fault finding suggestions<br />

Emergency stop failure<br />

The operator may have triggered an emergency stop of the printing machine<br />

• Check external emergency stop (e-stop) circuitry <strong>and</strong> switches<br />

• Check panel circuit breakers in external equipment<br />

• Check e-stop links between e-Brick units are intact (communications cables<br />

linking master-slave / slave/slave carry the e-Brick e-stop links)<br />

Fan failure<br />

The fan fails to operate when a lamp is started.<br />

• Check the electrical supply to the fan<br />

• Check the MCB supplying power to the fan, reset if necessary<br />

• Check the thermal overload device on the fan. If the switch has been tripped, reset it<br />

by pressing “1” button on the switch housing, then reset the fault on the touch screen<br />

On systems where an external air h<strong>and</strong>ling unit is used in place of the <strong>GEW</strong> system fan,<br />

this fault may show if the cooling air pressure does not reach a predetermined threshold<br />

within 90s of starting the cooling system<br />

<strong>System</strong> Safety Switch<br />

• Check the functionality of the system safety switch<br />

• Check integrity of wiring <strong>and</strong> connectors for the system safety switch<br />

<strong>GEW</strong> <strong>UV</strong> e-Brick HMI software operating <strong>manual</strong> 14 of 18