3.5.1. Warning indicators<br />
The e-Brick has three indicator LEDs, one for the internal 24V supply status, a second to show<br />
the main contactor (K1) status, <strong>and</strong> a third to indicate fault status. If the K1 LED fails to light when<br />
the lamp is selected <strong>and</strong> no other fault is present, please refer to <strong>GEW</strong> for service support.<br />
3.5.2. General faults<br />
Water cooling unit (chiller) failure<br />
The cooling unit has failed while the printing machine is running.<br />
• Check chiller MCB <strong>and</strong> reset if necessary<br />
• Ensure that the chiller is switched on<br />
• The chiller may have developed a fault; check the control panel to see if a fault is<br />
reported<br />
• Refer to the chiller <strong>manual</strong> for further fault finding suggestions<br />
Emergency stop failure<br />
The operator may have triggered an emergency stop of the printing machine<br />
• Check external emergency stop (e-stop) circuitry <strong>and</strong> switches<br />
• Check panel circuit breakers in external equipment<br />
• Check e-stop links between e-Brick units are intact (communications cables<br />
linking master-slave / slave/slave carry the e-Brick e-stop links)<br />
Fan failure<br />
The fan fails to operate when a lamp is started.<br />
• Check the electrical supply to the fan<br />
• Check the MCB supplying power to the fan, reset if necessary<br />
• Check the thermal overload device on the fan. If the switch has been tripped, reset it<br />
by pressing “1” button on the switch housing, then reset the fault on the touch screen<br />
On systems where an external air h<strong>and</strong>ling unit is used in place of the <strong>GEW</strong> system fan,<br />
this fault may show if the cooling air pressure does not reach a predetermined threshold<br />
within 90s of starting the cooling system<br />
<strong>System</strong> Safety Switch<br />
• Check the functionality of the system safety switch<br />
• Check integrity of wiring <strong>and</strong> connectors for the system safety switch<br />
<strong>GEW</strong> <strong>UV</strong> e-Brick HMI software operating <strong>manual</strong> 14 of 18