4.6.3.3. P3:Lamp output<br />

Pin connection Signal name Rating / connection<br />

3.6/9/12kW 22kW<br />

A1 A1 Lamp+<br />

A2 B1 Lamp-<br />

C1 C1 Shutter_Motor-<br />

C2 C2 Shutter_Motor+<br />

C3 C3 +24V<br />

C4 C4 Safety_switch<br />

C5 C5 Over_temp_switch<br />

C6 C6 Shutter_open<br />

C7 C7 Shutter_closed<br />

C8 C8 Chassis_in<br />

C9 C9 PT100<br />

C10 C10 PT100_rtn<br />

C11 C11 PhotoD+<br />

C12 C12 PhotoD-<br />

B1<br />

B2<br />

B3<br />

B4<br />

B5<br />

B6<br />

B7<br />

B8<br />

B9 PT100<br />

B10 PT100_rtn<br />

B11 PhotoD+<br />

B12 PhotoD-<br />

4.6.3.4. P4: Autodamper interface<br />

Lamp+ <strong>and</strong> Lamp- NOT SELV<br />

Warning! No <strong>user</strong> accessible signals!<br />

All signals relate to the <strong>GEW</strong> <strong>UV</strong> dryer.<br />

For safety reasons, connection shall only<br />

be made using <strong>GEW</strong> lamp cables<br />

Pin connection Signal name Rating / connection<br />

1 +24V Auto damper +24V supply<br />

2 0V Auto damper 0V return<br />

3 Control_voltage_0 0-10V output to damper<br />

4 Damper_feedback_0 0-10V feedback from damper<br />

5 Flow_OK ‘Volt free’ contact input from flow switch<br />

(water cooled applications only)<br />

6 Control_voltage_1 0-10V output to damper<br />

7 Damper_feedback_1 0-10V feedback from damper<br />

E<br />