4.6.3.3. P3:Lamp output<br />
Pin connection Signal name Rating / connection<br />
3.6/9/12kW 22kW<br />
A1 A1 Lamp+<br />
A2 B1 Lamp-<br />
C1 C1 Shutter_Motor-<br />
C2 C2 Shutter_Motor+<br />
C3 C3 +24V<br />
C4 C4 Safety_switch<br />
C5 C5 Over_temp_switch<br />
C6 C6 Shutter_open<br />
C7 C7 Shutter_closed<br />
C8 C8 Chassis_in<br />
C9 C9 PT100<br />
C10 C10 PT100_rtn<br />
C11 C11 PhotoD+<br />
C12 C12 PhotoD-<br />
B1<br />
B2<br />
B3<br />
B4<br />
B5<br />
B6<br />
B7<br />
B8<br />
B9 PT100<br />
B10 PT100_rtn<br />
B11 PhotoD+<br />
B12 PhotoD-<br />
4.6.3.4. P4: Autodamper interface<br />
Lamp+ <strong>and</strong> Lamp- NOT SELV<br />
Warning! No <strong>user</strong> accessible signals!<br />
All signals relate to the <strong>GEW</strong> <strong>UV</strong> dryer.<br />
For safety reasons, connection shall only<br />
be made using <strong>GEW</strong> lamp cables<br />
Pin connection Signal name Rating / connection<br />
1 +24V Auto damper +24V supply<br />
2 0V Auto damper 0V return<br />
3 Control_voltage_0 0-10V output to damper<br />
4 Damper_feedback_0 0-10V feedback from damper<br />
5 Flow_OK ‘Volt free’ contact input from flow switch<br />
(water cooled applications only)<br />
6 Control_voltage_1 0-10V output to damper<br />
7 Damper_feedback_1 0-10V feedback from damper<br />
E<br />
<strong>GEW</strong> <strong>UV</strong> e-Brick <strong>installation</strong> <strong>and</strong> operating <strong>manual</strong> 26 of 49