PSU failure<br />

A fault has been detected within the e-Brick.<br />

• Check 3 phase supply is on <strong>and</strong> that all three phases are available<br />

• Check 24V LED is illuminated, if not then internal 24Vdc may be faulty<br />

• Check K1 LED illuminates when lamp is selected<br />

• Ensure that the lamp cable is connected<br />

• Ensure that other cables are undamaged <strong>and</strong> correctly connected<br />

PSU over temperature<br />

The e-Brick has reported a high internal temperature.<br />

• Let the PSU cool down before re-striking<br />

• Check that the cooling fans are running<br />

• Check filters<br />

• If the e-Brick is mounted in a cabinet, check for air blockages <strong>and</strong> that adequate<br />

cooling capacity has been allowed.<br />

PSU drive fault<br />

A fault has been detected within the e-Brick control circuitry<br />

• Switch off power to the affected e-Brick<br />

• Restore power <strong>and</strong> attempt to restart lamp<br />

• If fault continues to appear, call <strong>GEW</strong> for service<br />

Lamp failure<br />

No current flow was detected through the lamp.<br />

Warning! When resolving a lamp failure it is important to let the lamp cool before<br />

attempting to restart the system.<br />

• Check all electrical connections relating to the lamp.<br />

• Check the physical state of the lamp; change the lamp if it has operated for<br />

>1000h. Instructions for changing the lamp are given in the lamp head <strong>user</strong><br />

<strong>manual</strong>. If a new lamp fails, call <strong>GEW</strong> for advice.<br />

• Let the lamp cool down before re-striking.<br />

Safety switch failure<br />

On systems with lamp heads mounted on hinged brackets, this alarm will indicate that the<br />

lamp head has been hinged open.<br />

• Check that the lamp is firmly seated in the outer casing<br />

• Check that the lamp head is closed (hinged head)<br />

• If this fault occurs with the lamp head hinged closed then check the alignment of<br />

the interlock arm with the interlock switch at the front of the lamp head.<br />

Lamp over temperature<br />

The lamp head overheats. Overheating may be caused by problems in the lamp head.<br />

Advice! Let the lamp cool down before re-striking.<br />

• Check that the fan is running <strong>and</strong> that its rotation is correct<br />

• Check that the damper operates normally, check for air blockage<br />

• Check flexible ducting for obstructions<br />

• Check electrical connections between the e-Brick <strong>and</strong> the lamp head<br />

• Check the lamp chassis is fully inserted in the lamp head; ensure that the plug to<br />

the lamp head is fully engaged<br />