4.6.3.1. P1: Press interface<br />

Pin connection Signal name Rating / connection<br />

A1 Station_ready ‘Volt free’ relay output to press.<br />

A7 Station_ready_rtn Contact rating 1A @ 24Vdc / 120Vac<br />

A4 Fan_start<br />

24VDC relay output to drive fan contactor<br />

A10 Fan_start_rtn coil [also available on P7]<br />

B1 E-stop<br />

‘Volt free’ contact input from press<br />

B2 E-stop_rtn<br />

A5 Fan_healthy ‘Volt free’ contact input from press<br />

A11 Fan_healthy_rtn [Also available on P7]<br />

A6 Speed 0-10V speed signal from press (ISO)<br />

A12 Speed_rtn 0V reference for press speed signal (ISO)<br />

A2 Ready<br />

‘Volt free’ relay output to press.<br />

A8 Ready_rtn Contact rating 1A @ 24Vdc / 120Vac<br />

A3 Fault<br />

‘Volt free’ relay output to press.<br />

A9 Fault_rtn<br />

Contact rating 1A @ 24Vdc / 120Vac<br />

B3 HMI_Comms_rtn 0V for communications<br />

B4 Ext_CAN_rtn 0V (ISO) for Canbus interface<br />

B5 HMI_Comms_Tx RS232 to HMI or RS485+<br />

B6 HMI_Comms_Rx RS232 from HMI or RS485-<br />

B7 Ext_CAN+ CANbus interface for customer<br />

B8 Ext_CAN- CANbus interface for customer<br />

B9 Aux 24V 200mA maximum (thermally fused output)<br />

B10 Impression ‘Volt free’ contact input from press<br />

B11 Impression_rtn<br />

B12 0V 0V reference for e-Brick<br />

4.6.3.2. P2: Communications port (out)<br />

P2: Communications port (Master & Slave)<br />

Pin connection Signal name Rating / connection<br />

1 gCAN+ <strong>GEW</strong> CANbus<br />

2 gCAN- <strong>GEW</strong> CANbus<br />

3 E-stop<br />

4 E-stop_rtn<br />

5<br />

6<br />

<strong>GEW</strong>_RS232_TxD<br />

<strong>GEW</strong>_RS232_RxD<br />

Factory use only<br />

7<br />

E<br />

gCAN_rtn <strong>GEW</strong> CANbus<br />

‘Volt free’ safety relay output to E-stop input<br />

on next slave e-Brick.<br />

Contact rating 1A 120Vac / 3A 24Vdc<br />