4.6.3.5. P5: Power input<br />

Pin connection Signal name Rating / connection<br />

9/12kW 3.6kW 22kW<br />

A1 A1 A1 L1<br />

A2 B1 L2<br />

A3 C1 L3<br />

A2 N<br />

Frame Frame Frame PE<br />

B1 B1 F1 Fan_healthy<br />

B2 B2 F2 Fan_healthy_rtn<br />

B3 B3 F3 Auxiliary_n/o<br />

B4 B4 F4 Auxiliary_n/o_rtn<br />

B5 B5 F5 Auxiliary_n/c<br />

B6 B6 F6 Auxiliary_n/c_rtn<br />

B7 B7 F7 Chiller_OK<br />

B8 B8 F8 Chiller_OK_rtn<br />

4.6.3.6. Protective Earth terminal<br />

Mains supply input, for ratings see<br />

Table 5<br />

L1-L3 & N connections NOT SELV<br />

Volt free’ contact input from press<br />

[Also available on P7]<br />

‘Volt free’ auxiliary n/o contact<br />

output. Contact rating 1A @ 24Vdc<br />

/ 120Vac<br />

‘Volt free’ auxiliary n/c contact<br />

output. Contact rating 1A @ 24Vdc<br />

/ 120Vac<br />

‘Volt free’ contact input from chiller<br />

An M6 stud is provided on the rear of the e-Brick housing to permit Protective Earth (PE)<br />

bonding during <strong>installation</strong>. Note that the mains supply earth is through P5.<br />

4.6.3.7. P6(P60): Communication port (in)<br />

P6: HMI (Master)<br />

Pin connection Signal name (Master) Rating / connection<br />

1 24V 24V output to HMI<br />

2 0V 0V output to HMI<br />

3 HMI_Comms_Tx RS232 to HMI or RS485+<br />

4 HMI_Comms_Rx RS232 from HMI or RS485-<br />

5 Ext_CAN+ CANbus interface for customer<br />

6 Ext_CAN- CANbus interface for customer<br />

7 HMI_Comms_rtn 0V for communications<br />

E<br />

P60: Communications port (Slave, in)<br />

Pin connection Signal name (Slave) Rating / connection<br />

1 gCAN+ <strong>GEW</strong> CANbus<br />

2 gCAN- <strong>GEW</strong> CANbus<br />

3 E-stop<br />

4 E-stop_rtn<br />

5 N/c<br />

6 N/c<br />

7 gCAN_rtn <strong>GEW</strong> CANbus<br />

E<br />

‘Volt free’ contact input from E-stop<br />

output on previous master / slave e-<br />

Brick.<br />

<strong>GEW</strong> <strong>UV</strong> e-Brick <strong>installation</strong> <strong>and</strong> operating <strong>manual</strong> 27 of 49