4.5. General Data<br />
4.5.1. Electrical supply<br />
The 9/12/22kW e-Brick requires a 3-Phase mains supply with a Protective Earth<br />
connection (3P+E); note that no neutral connection is made. The 3.6kW e-Brick requires a<br />
single-phase mains supply with a Protective Earth connection. Refer to Table 5 for operating<br />
Voltage range <strong>and</strong> peak supply current per phase.<br />
Power factor is typically 0.9 for all e-Brick variants so no additional power factor correction<br />
is required.<br />
e-Brick Nominal Supply Supply Peak current Supply Maximum<br />
variant Voltage (V) Voltage (V) / phase (A) Frequency Power<br />
3.6kW 240V 216-264V 20 50-60Hz