03.08.2013 Views

Hydrovar Pump Controller Installation & Operation Manual

Hydrovar Pump Controller Installation & Operation Manual

Hydrovar Pump Controller Installation & Operation Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical Data<br />

5.1 General Technical Data<br />

Ambient temperature: 0° C ... +40° C, 32º F... +104º F<br />

At higher temperatures reduce the output current as shown below or<br />

upsize to the next largest HYDROVAR.<br />

The enclosure rating of the HYDROVAR is IP55 however, please note<br />

the following:<br />

• Protect the HYDROVAR from direct sunlight!<br />

• Protect the HYDROVAR from direct rainfall<br />

• Outdoor installation without protection from sun will void warranty!<br />

Storage temperature: -25° C ... +55° C, -10º F ... +130º F<br />

Humidity: RH maximum 50% at 104º F, unlimited<br />

RH maximum 90% at 70º F, maximum 30 days per year<br />

75% average per year (class F)<br />

Condensation is not allowed and will void warranty!<br />

During long periods of inactivity or shutdown, the HYDROVAR should<br />

remain connected to the power supply but turned off to prevent<br />

inadvertant pump run. This will maintain power to the internal heater and<br />

reduce internal condensation.<br />

Air pollution: The air may contain dry dust as found in workshops where there is<br />

excessive dust due to machines. Excessive amounts of dust, acids,<br />

corrosive gases, salts etc. are not permitted<br />

Altitude: Maximum 1000 m, 3280 feet above sea level.<br />

At sites over 1000 m above sea level, the maximum output power should<br />

be de-rated by 1% for every additional 100 m. For installations higher than<br />

2000 m above sea level, please contact your local distributor.<br />

Class of protection: IP 55, NEMA 4 (Indoor use only)<br />

Certifications: CE, UL, C-Tick, cUL<br />

Maximum Output Current (%)<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

0 10 20 30 40 50 60<br />

13<br />

Maximum Ambient Temperature (ºC)