Product Overview<br />
in a multi-pump-system depends on the system requirements (i.e. in a 6 pump system 2 or more Master<br />
controllers can be used to increase reliability, and up to 4 Basic controllers without control card.<br />
Minimum requirement: 1 Master controller and the other pumps equipped with Basic controllers.<br />
To increase the reliability of a system, (in the event of a Master controller failure) a second Master controller can<br />
be used.<br />
Full-featured possibility: Each pump is equipped with a Master controller.<br />
In this mode it is possible to run all pumps in cascade serial mode and synchronous mode as well.<br />
This configuration allows each pump to become the lead pump. This also ensures a proper operation if one<br />
Master controller fails. In this case another HYDROVAR takes control. This ensures that the operating hours of<br />
each pump will be the same to ensure even wear of the pumps.<br />