ECM Background Information <strong>Mobile</strong> <strong>Generator</strong> <strong>Repair</strong><br />

4.3 Display Variables and Values<br />

See Graphic: wc_gr002944<br />

<strong>Generator</strong> Variables<br />

The values shown in the top line of the ECM display are all variables<br />

from the generator side of the machine. They are:<br />

(1) voltage (V)<br />

(2) phase (Ø) (or leg for single phase)<br />

(3) amperage (A)<br />

(4) frequency (Hz)<br />

Engine Variables<br />

The values shown in the lower line of the ECM display are all variables<br />

from the engine side of the machine. They are:<br />

(5) engine oil pressure (psi)<br />

(6) fuel tank quantity (shown in percentage of capacity)<br />

(7) engine temperature (°F)<br />

(8) battery voltage (V)<br />

Blinking Values<br />

When a value on the ECM display blinks on and off, it signifies that the<br />

variable (temperature, fuel capacity, etc.) is in a pre-alarm state. For<br />

example, the value for the temperature reading will blink when the<br />

temperature of the generator is below 23°C (74°F). This simply<br />

signifies that the manifold heater (or glow plugs) will be energized to<br />

aid in engine starting. The fuel capacity reading will blink when it is<br />

below 25%. This tells the operator that the generator will be requiring<br />

fuel soon. See Section Additional Variables Monitored by the ECM.<br />

Note: If your generator has a block heater, the temperature reading<br />

should not blink. If it does, check the block heater to make sure it is<br />

functioning properly.<br />

ND (No Data), 0 (zero), or Blank Values<br />

When a value on the ECM display reads ND, 0 (zero), or is blank, it<br />

signifies that there is no data available for the variable.<br />