Disassembly and Assembly G 70<br />

9.4 Removing the Roof<br />

Prerequisites Machine shut down<br />

Crane capable of lifting 227 kg (500 lb)<br />

Procedure Follow the procedure below to remove the roof.<br />

1. Disconnect the battery.<br />

2. Remove the doors (a).<br />

3. Remove the front and rear access panels (b and c).<br />

4. Remove the screws that secure the roof to the side panels (d).<br />

5. Remove the screws that secure the control panel enclosure (e) to the lifting<br />

structure (f).<br />

6. Remove the screws that secure the door latch (g) to the lifting structure and<br />

remove the door latch.<br />

This procedure continues on the next page.<br />