Output Voltage Troubleshooting G 70<br />

8.3 Checking the Lug Door Switch<br />

Prerequisites <strong>Generator</strong> shut down<br />

Procedure Follow the procedure below to check the lug door switch.<br />

1. Open the large hinged panel. Remove the “key” (latch) (a) from the lug door and<br />

place in the slot of the lug door switch. NOTICE: Do not place anything but the<br />

key into the slot of the lug door switch.<br />

2. Disconnect the blue wire and the orange wires of the lug door switch.<br />

Disconnect the blue/white wire at the AVR.<br />

3. With the key in the lug door switch, check for continuity between the blue wire<br />

and blue/white wire.<br />

Is there continuity?<br />

Yes ____ No ____<br />

Continue. The lug door switch has failed; replace it.<br />

4. Remove the key from the lug door switch.<br />

5. Check for continuity between the blue wire and the blue/white wire.<br />

Is there continuity?<br />

Yes ____ No ____<br />

The lug door switch has failed; replace it. Reconnect the blue and blue/white wires;<br />

then continue.<br />

6. Check for continuity between the orange wires.<br />

Is there continuity?<br />

This procedure continues on the next page.<br />

wc_tx000958gb.fm 68<br />

wc_gr005482<br />

Yes ____ No ____<br />

Continue. The lug door switch has failed; replace it.<br />