ECM/Sensor Troubleshooting G 70<br />

5.7 Calibrating ECM DC Display<br />

Prerequisites Functioning generator<br />

Procedure Follow the procedure below to calibrate the ECM DC voltage (12V battery) display.<br />

1. Measure the voltage across the machine’s 12V battery using a multimeter.<br />

Note: This procedure works best when the battery voltage measures 12.6 VDC.<br />

2. Place the start switch in the REMOTE START position.<br />

3. Open the control panel to gain access to the ECM.<br />

4. Slide the number 2, Dual-In-line Package (DIP) switch to the ON position and<br />

then back to the OFF position. This resets the DC voltage display.<br />

The ECM DC voltage display is now calibrated.<br />