G 70 Schematics<br />
10.2 Engine Wiring Components—John Deere with ECU<br />
Ref. Description Ref. Description<br />
1 Plug 1 — engine sender inputs 14 Battery<br />
2 Plug 2 — engine start/run outputs 15 ECM 10A fuse<br />
3 Main circuit breaker (3-phase lugs) 16 Starter relay<br />
4 Shunt trip coil 17 Starter<br />
5 Emergency stop switch 18 Alternator<br />
6 Engine Control Module (ECM) 19 B+ terminal block<br />
7 Safety interlock switch 20 System 10A fuse<br />
8 Remote start terminals 21 System 30A fuse<br />
9 Fuel level sender 22 Harness connector<br />
10 Intake heater 23 CAN bus connector<br />
11 Slave preheat relay 24 Diagnostic connector<br />
12 Mechanical lugs (3 phase) 25 ECU harness connector<br />
13 Start switch 26 Hour meter switch<br />
ECM Plug 1 Wires ECM Plug 2 Wires<br />
Pin Wire Description Pin Wire Description<br />
10 Gr/61 Emergency stop 5 R/18 Battery + (for relays)<br />
3 W/L/56 Oil pressure sender 1 Y/63 Crank (12V output)<br />
9 Or/60 Remote start 2 V/64 Run/Fuel (12V output)<br />
12 W/V/62 Fuel level 3 73 Remote annunciator (NA)<br />
8 B/59 Battery – 4 75 Remote annunciator (NA)<br />
7 R/53 Battery + (for ECM board) - - ---<br />
Wire Colors<br />
B Black R Red Y Yellow Or Orange<br />
G Green T Tan Br Brown Pr Purple<br />
L Blue V Violet Cl Clear Sh Shield<br />
P Pink W White Gr Gray LL Light blue<br />
wc_tx000945gb.fm 99