G 70 Troubleshooting Engine Start System<br />

7.6 Checking the Intake Air Heater Relay<br />

Prerequisites Battery voltage measuring 11–13 VDC<br />

Procedure Follow the procedure below to check the intake air heater relay.<br />

1. Locate the intake air heater relay.<br />

2. Measure the voltage between terminal 30 (red wire #11) of the intake air heater<br />

relay and ground.<br />

Is at least 9.8 VDC measured?<br />

Yes____ No____ Your reading<br />

Continue. <strong>Repair</strong> or replace red wire #11.<br />

3. Place the START/RUN switch in the ON position.<br />

4. Measure the voltage between terminal 86 (grey wire #65) and ground during the<br />

preheat cycle. Note: This cycle only lasts a few seconds.<br />

Is at least 9.8 VDC measured?<br />

Yes____ No____ Your reading<br />

Continue. <strong>Repair</strong> or replace grey wire #65.<br />

5. Check the connection to ground of black wire #13 at terminal 85.<br />

Is there a path to ground?<br />

Yes____ No____ Your reading<br />

Continue. <strong>Repair</strong> or replace wire #13.<br />

6. Place the START/RUN switch in the ON position.<br />

7. Measure the voltage between terminal 87 (red wire #12) and ground.<br />

Is at least 9.8 VDC measured?<br />

The intake air heater relay has now been checked.<br />

wc_tx000957gb.fm 63<br />

Yes____ No____ Your reading<br />

The intake air heater relay is<br />

OK.<br />

The intake air heater relay<br />

has failed; replace it.