G 70 ECM/Sensor Troubleshooting<br />

5.1 Checking Power to the ECM<br />

Prerequisites Fully-charged (12+ Volts) battery<br />

Cable running between battery and starter relay is in good conditon and connections<br />

are good.<br />

Procedure Follow the procedure below to check incoming power to the ECM.<br />

1. Check the voltage between red wire #51 at B+ terminal strip and ground.<br />

Is at least 9.8 VDC measured?<br />

Yes ____ No ____ Your reading<br />

Continue. Check red wire #51 and all wiring between B+<br />

terminal strip and the battery.<br />

2. Check voltage between red wire #49 at START/RUN switch and ground.<br />

Is at least 9.8 VDC measured?<br />

Yes ____ No ____ Your reading<br />

Continue. <strong>Repair</strong> red wire #49.<br />

3. Place the START/RUN switch in the ON position.<br />

4. Check the voltage between red wire #53 at START/RUN switch and ground.<br />

Is at least 9.8 VDC measured?<br />

Yes ____ No ____ Your reading<br />

Continue.<br />

Replace the START/RUN switch.<br />

This procedure continues on the next page.<br />