ECM Background Information <strong>Mobile</strong> <strong>Generator</strong> <strong>Repair</strong><br />

4.7 ECM Automatic Engine Shutdown Conditions<br />

The engine protection system includes two automatic shutdown<br />

conditions: engine overcrank and low fuel. The ECM will also shut<br />

down the engine if an over-current condition exists.<br />

When the ECM has shut down the unit due to one of the faults, the<br />

ECM will display the fault and other pertinent information to aid in<br />

diagnosing the problem. RECORD ALL THE INFORMATION LISTED<br />

on the display, then refer to the following sections to diagnose and<br />

rectify the problem.<br />

When the engine has shut down due to something outside the control<br />

of the ECM, the ECM will display “ENGINE STOPPED”.<br />

Fault Pre-alarm setpoint Shutdown setpoint<br />

Overcrank n/a After third attempt<br />

Fuel level 15% 5%<br />

wc_tx001066gb.fm 34