Repair Manual Mobile Generator - Wacker Neuson
Repair Manual Mobile Generator - Wacker Neuson
Repair Manual Mobile Generator - Wacker Neuson
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ECM Background Information <strong>Mobile</strong> <strong>Generator</strong> <strong>Repair</strong><br />
4.7 ECM Automatic Engine Shutdown Conditions<br />
The engine protection system includes two automatic shutdown<br />
conditions: engine overcrank and low fuel. The ECM will also shut<br />
down the engine if an over-current condition exists.<br />
When the ECM has shut down the unit due to one of the faults, the<br />
ECM will display the fault and other pertinent information to aid in<br />
diagnosing the problem. RECORD ALL THE INFORMATION LISTED<br />
on the display, then refer to the following sections to diagnose and<br />
rectify the problem.<br />
When the engine has shut down due to something outside the control<br />
of the ECM, the ECM will display “ENGINE STOPPED”.<br />
Fault Pre-alarm setpoint Shutdown setpoint<br />
Overcrank n/a After third attempt<br />
Fuel level 15% 5%<br />
wc_tx001066gb.fm 34