G 70 Disassembly and Assembly<br />

9.6 Installing the Voltage Selector Switch<br />

Prerequisites Machine shut down<br />

New Voltage Selector Switch (VSS)<br />

Procedure Follow the procedure below to install the Voltage Selector Switch (VSS).<br />

WARNING<br />

Electric shock hazard. High voltage exists inside at voltage selector switch when<br />

the engine is running. High voltage can cause severe injury or death.<br />

Shut down the machine before performing this procedure.<br />

1. Attach the support plate (g) to the VSS (e).<br />

f<br />

2. Secure the VSS and support plate to the box.<br />

3. Install the mounting plate (f).<br />

4. Connect the wires to the VSS (e).<br />

5. Install the switch handle (b), locking ring (c), and face plate (d).<br />

6. Install the cover (a) to the voltage selector switch box.<br />

7. Install the air cleaner assembly.<br />

The procedure is now complete.<br />

wc_tx001068gb.fm 87<br />

g<br />

e<br />

wc_gr005897<br />

c d<br />

wc_gr005890