G 70 Troubleshooting Engine Start System<br />
7.4 Checking the Starter Relay<br />
Prerequisites Battery voltage measuring 11–13 VDC<br />
Procedure Follow the procedure below to check the starter relay.<br />
1. Locate the starter relay.<br />
2. Check the voltage between the red wire #50 and ground.<br />
Is at least 9.8 VDC measured?<br />
Yes ____ No ____ Your reading<br />
Continue. <strong>Repair</strong> or replace red wire #50.<br />
3. Place the START/RUN switch in the ON position.<br />
4. Measure the voltage between red wire #422 and ground during cranking.<br />
Is at least 9.8VDC measured?<br />
Yes ____ No ____ Your reading<br />
Continue. <strong>Repair</strong> or replace red wire #422.<br />
5. Check the connection to ground of both black wires.<br />
Is there a path to ground?<br />
Yes ____ No ____ Your reading<br />
Continue. <strong>Repair</strong> or replace both black wires.<br />
6. Place the START/RUN switch in the ON position.<br />
7. Measure the voltage between the red wire (R) running to the starter solenoid<br />
and ground.<br />
Is at least 9.8 VDC measured?<br />
Yes ____ No ____ Your reading<br />
The starter relay is OK. The starter relay has failed;<br />
replace it.<br />
The starter relay has now been checked. Continue with Section 7.5 Checking the<br />
Starter Solenoid.<br />
wc_tx000957gb.fm 61