G 70 Troubleshooting Engine Start System<br />

7.4 Checking the Starter Relay<br />

Prerequisites Battery voltage measuring 11–13 VDC<br />

Procedure Follow the procedure below to check the starter relay.<br />

1. Locate the starter relay.<br />

2. Check the voltage between the red wire #50 and ground.<br />

Is at least 9.8 VDC measured?<br />

Yes ____ No ____ Your reading<br />

Continue. <strong>Repair</strong> or replace red wire #50.<br />

3. Place the START/RUN switch in the ON position.<br />

4. Measure the voltage between red wire #422 and ground during cranking.<br />

Is at least 9.8VDC measured?<br />

Yes ____ No ____ Your reading<br />

Continue. <strong>Repair</strong> or replace red wire #422.<br />

5. Check the connection to ground of both black wires.<br />

Is there a path to ground?<br />

Yes ____ No ____ Your reading<br />

Continue. <strong>Repair</strong> or replace both black wires.<br />

6. Place the START/RUN switch in the ON position.<br />

7. Measure the voltage between the red wire (R) running to the starter solenoid<br />

and ground.<br />

Is at least 9.8 VDC measured?<br />

Yes ____ No ____ Your reading<br />

The starter relay is OK. The starter relay has failed;<br />

replace it.<br />

The starter relay has now been checked. Continue with Section 7.5 Checking the<br />

Starter Solenoid.<br />