ECM Background Information <strong>Mobile</strong> <strong>Generator</strong> <strong>Repair</strong><br />
4.9 Removing and Installing the ECM<br />
See Graphic: wc_gr003316<br />
Removal:<br />
4.9.1 Remove the nut securing the hour meter switch (a) and the nut<br />
securing the start switch (b) to the panel.<br />
4.9.2 Disconnect the four harness plugs (e).<br />
4.9.3 Remove the three red wires (d) from the start switch. Remove the start<br />
switch, the hour meter switch, and the ECM from the panel.<br />
Note: Replacement ECMs include start and hour meter switches.<br />
4.9.4 Remove the screws (c) securing the ECM to the panel.<br />
4.9.5<br />
Installation:<br />
Secure the ECM to the panel with screws (c).<br />
4.9.6 Secure the hour meter (a) and the start switch (b) to the control panel.<br />
4.9.7 Reconnect the four harness plugs (e).<br />
4.9.8 Re-install the three red wires (d) to the start switch.<br />
c<br />
wc_tx001066gb.fm 36<br />
c<br />
b<br />
a<br />
e e<br />
d<br />
wc_gr003316