Logic analyzer<br />

10.10.1 Description of the work screen<br />

<strong>Operating</strong> <strong>manual</strong><br />

The screen for the logic analyzer is divided into the following areas or display windows:<br />

1. Status window.<br />

It graphically shows the status of each selected signal. It is divided into two areas: Variables area<br />

and status area.<br />

The variables area shows the names or symbols of the logic signals to be analyzed.<br />

The status area shows the status of each variable in square waves. The line for logic level 0 is<br />

shown with a thicker line.<br />

Likewise, it shows a vertical red line to indicate the TRIGGER point and another green vertical<br />

line to indicate the cursor position.<br />

The vertical green line for the cursor may be moved along the trace and helps measure the time<br />

between two points of the trace.<br />

The status area is divided into several vertical stripes. Each stripe represents the amount of time<br />

defined by the "time base" constant.<br />

The "time base" constant sets the resolution of the logic signals and, after being set by the user,<br />

may be modified as often as desired. The "time base" is inversely proportional to the resolution<br />

of the signals; thus, the lower the "time base" the greater the signal resolution and vice versa.<br />

2. Cycles window<br />

This window shows several vertical lines "¦". Each one indicates the instant when the execution<br />

of a new cycle of the PLC program starts.<br />

It permits maintaining a relationship between the flux of the logic signals and the duration of each<br />

PLC execution cycle.