<strong>Programming</strong> <strong>manual</strong><br />

11.<br />

HIGH-LEVEL LANGUAGE PROGRAMMING<br />

Variables<br />

<strong>CNC</strong> <strong>8035</strong><br />

·T· MODEL<br />

(SOFT V16.3X)<br />

·228·<br />

PRGFPR<br />

PRGFIN<br />

FRO<br />

DNCFRO<br />

PLCFRO<br />

<strong>CNC</strong>FRO<br />

PLCCFR<br />

PRGFRO<br />

It returns the feedrate, in mm/turn or inches/turn selected by PLC. If it has a value of 0 it means that<br />

it is not selected.<br />

It returns the feedrate, in mm/turn or inches/turn selected by program.<br />

Read-only variables associated with function G32<br />

It returns the feedrate selected by program, in 1/min.<br />

Likewise, the <strong>CNC</strong> variable FEED, associated with G94, indicates the resulting feedrate in mm/min<br />

or inches/min.<br />

Read-only variables associated with the override<br />

It returns the feedrate override (%) currently selected at the <strong>CNC</strong>. It is given in integer values between<br />

0 and "MAXFOVR" (maximum 255).<br />

This feedrate percentage may be indicated by program, by PLC, by DNC or by the front panel; the<br />

<strong>CNC</strong> selects one of them and the priority (from the highest to the lowest) is: by program, by DNC,<br />

by PLC and from the front panel switch.<br />

It returns the feedrate override % currently selected by the DNC. If it has a value of 0 it means that<br />

it is not selected.<br />

It returns the feedrate override % currently selected by the PLC. If it has a value of 0 it means that<br />

it is not selected.<br />

It returns the feedrate override % currently selected by the switch.<br />

It returns the feedrate percentage currently selected by the PLC's execution channel.<br />

Read-write variables associated with the override<br />

This variable may be used to read or modify the feedrate override percentage currently selected<br />

by program. It is given in integer values between 0 and "MAXFOVR" (maximum 255). If it has a value<br />

of 0 it means that it is not selected.<br />

(P110=PRGFRO)<br />

It assigns to P110 the % of feedrate override selected by program.<br />

(PRGFRO=P111)<br />

It sets the feedrate override % selected by program to the value of P111.