2G6<br />

(3) Exposure<br />

The charged surface of the drum (A) is then scanned by the laser beam from the laser scanner unit (B).<br />

Laser beam<br />

(LSU)<br />

(A)<br />

Figure 2-1-10 Exposure<br />

The laser beam (780 nm wavelength) beam is dispersed as the polygon motor (polygon mirrors) revolves to reflect the<br />

laser beam over the drum. Various lenses and mirror are housed in the scanner unit, adjust the diameter of the laser<br />

beam, and focalize it at the drum surface.<br />

2-1-10