2G6<br />

(1) No image appears<br />

(entirely white).<br />

Causes<br />

1. Defective process unit installation.<br />

2. No transfer charging.<br />

3. Defective laser scanner unit.<br />

Causes<br />

1. Defective process unit installation.<br />

2. No transfer charging.<br />

3. Defective laser scanner unit.<br />

Check procedures/corrective measures<br />

Check that the process unit is inserted correctly.<br />

Check the transfer bias output on the high voltage unit. This requires<br />

removal of the left cover and the test equipment. Replace the high<br />

voltage unit if high voltage potential is not available on<br />

the unit (See page 1-6-12).<br />

The scanner components within the scanner may be disordered.<br />

Replace the laser scanner unit if necessary (See page 1-6-28).<br />

(2) No image appears<br />

(entirely black).<br />

Causes<br />

1. No main charging.<br />

Causes<br />

1. No main charging.<br />

A. Broken main charger wire.<br />

B. Leaking main charger housing.<br />

C. The connector terminals of the high voltage<br />

board make poor contact.<br />

D. Defective engine PWB (K0010).<br />

E. Defective high voltage unit.<br />

Check procedures/corrective measures<br />

Replace the process unit.<br />

Replace the process unit.<br />

Reinsert the connector. Also check for continuity within the<br />

connector cable. If none, remedy or replace the cable.<br />

Replace the engine PWB (K0010) and check for correct operation.<br />

Replace the high voltage unit and check for correct operation.<br />

(3) Image is too<br />

light.<br />

Causes<br />

1. Insufficient toner.<br />

2. Deteriorated developer.<br />

3. Dirty or deteriorated drum.<br />

Causes<br />

1. Insufficient toner.<br />

2. Deteriorated developer.<br />

3. Dirty or deteriorated drum.<br />

Check procedures/corrective measures<br />

If the add toner indicator lights, replace the toner container.<br />

Replace the process unit.<br />

Replace the process unit.<br />

1-5-13