FS-1030D Service Manual - kyocera
FS-1030D Service Manual - kyocera
FS-1030D Service Manual - kyocera
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
2G6<br />
(1) No image appears<br />
(entirely white).<br />
Causes<br />
1. Defective process unit installation.<br />
2. No transfer charging.<br />
3. Defective laser scanner unit.<br />
Causes<br />
1. Defective process unit installation.<br />
2. No transfer charging.<br />
3. Defective laser scanner unit.<br />
Check procedures/corrective measures<br />
Check that the process unit is inserted correctly.<br />
Check the transfer bias output on the high voltage unit. This requires<br />
removal of the left cover and the test equipment. Replace the high<br />
voltage unit if high voltage potential is not available on<br />
the unit (See page 1-6-12).<br />
The scanner components within the scanner may be disordered.<br />
Replace the laser scanner unit if necessary (See page 1-6-28).<br />
(2) No image appears<br />
(entirely black).<br />
Causes<br />
1. No main charging.<br />
Causes<br />
1. No main charging.<br />
A. Broken main charger wire.<br />
B. Leaking main charger housing.<br />
C. The connector terminals of the high voltage<br />
board make poor contact.<br />
D. Defective engine PWB (K0010).<br />
E. Defective high voltage unit.<br />
Check procedures/corrective measures<br />
Replace the process unit.<br />
Replace the process unit.<br />
Reinsert the connector. Also check for continuity within the<br />
connector cable. If none, remedy or replace the cable.<br />
Replace the engine PWB (K0010) and check for correct operation.<br />
Replace the high voltage unit and check for correct operation.<br />
(3) Image is too<br />
light.<br />
Causes<br />
1. Insufficient toner.<br />
2. Deteriorated developer.<br />
3. Dirty or deteriorated drum.<br />
Causes<br />
1. Insufficient toner.<br />
2. Deteriorated developer.<br />
3. Dirty or deteriorated drum.<br />
Check procedures/corrective measures<br />
If the add toner indicator lights, replace the toner container.<br />
Replace the process unit.<br />
Replace the process unit.<br />
1-5-13