2G6<br />
Problem Causes Check procedures/corrective measures<br />
(6)<br />
The registration solenoid<br />
does not operate.<br />
(7)<br />
The switchback solenoid<br />
does not operate.<br />
(8)<br />
The eraser lamp<br />
does not turn on.<br />
(9)<br />
The heater lamp<br />
does not turn on.<br />
(10)<br />
The heater lamp<br />
does not turn off.<br />
(11)<br />
Main charging is not<br />
performed.<br />
(12)<br />
Transfer charging is<br />
not performed.<br />
Broken registration solenoid<br />
coil.<br />
Poor contact in the registration<br />
solenoid connector<br />
terminals.<br />
Defective engine PWB<br />
(K0010).<br />
Broken switchback solenoid<br />
coil.<br />
Poor contact in the<br />
switchback solenoid connector<br />
terminals.<br />
Defective engine PWB<br />
(K0010).<br />
Poor contact in the eraser<br />
lamp connector terminals.<br />
Defective eraser lamp.<br />
Defective engine PWB<br />
(K0010).<br />
Broken wire in heater<br />
lamp.<br />
Thermal cutout triggered.<br />
Defective engine PWB<br />
(K0010).<br />
Dirty sensor part of the<br />
fuser thermistor.<br />
Broken main charger wire.<br />
Leaking main charger<br />
housing.<br />
Poor contact in the high<br />
voltage board connector<br />
terminals.<br />
Defective engine PWB<br />
(K0010).<br />
Defective high voltage<br />
unit.<br />
Poor contact in the high<br />
voltage unit connector terminals.<br />
Defective engine PWB<br />
(K0010).<br />
Defective high voltage<br />
unit.<br />
Check for continuity across the coil. If none, replace the registration<br />
solenoid.<br />
Reinsert the connector. Also check for continuity within the connector<br />
cable. If none, remedy or replace the cable.<br />
Replace the engine PWB (K0010). See page 1-6-9.<br />
Check for continuity across the coil. If none, replace the<br />
switchback solenoid.<br />
Reinsert the connector. Also check for continuity within the connector<br />
cable. If none, remedy or replace the cable.<br />
Replace the engine PWB (K0010). See page 1-6-9.<br />
Reinsert the connector. Also check for continuity within the connector<br />
cable. If none, remedy or replace the cable.<br />
Check for continuity. If none, replace the eraser lamp. See page<br />
1-6-30.<br />
If the eraser lamp turns on when YC14-2 on the engine PWB<br />
(K0010) is held low, replace the engine PWB (K0010). See<br />
page 1-6-9.<br />
Check for continuity across heater lamp. If none, replace the<br />
heater lamp. See page 1-6-22.<br />
Check for continuity across thermal cutout. If none, remove the<br />
cause and replace the thermal cutout. See page 1-6-26.<br />
Replace the engine PWB (K0010). See page 1-6-9.<br />
Check visually and clean the fuser thermistor sensor parts.<br />
See page 1-5-13.<br />
See page 1-5-13.<br />