Connector Pin No. Signal I/O Voltage Description<br />

CN1<br />

Connected<br />

to the main<br />

PWB<br />

1 Neutral O 120 V AC Power supply for heater lamp<br />

220 - 240 V AC<br />

3 Live O 120 V AC Power supply for heater lamp<br />

220 - 240 V AC<br />

YC2<br />

Connected<br />

to the High<br />

voltage unit<br />

YC3<br />

Connected<br />

to the<br />

cooling fan<br />

YC4<br />

Connected<br />

to the fuser<br />

thermistor<br />

YC5<br />

Connected<br />

to the AC<br />

inlet<br />

1 +5V O 5 V DC 5 V DC power supply<br />

2 +5V O 5 V DC 5 V DC power supply<br />

3 FAN I 0/12/24 V DC Cooling fan rotation: High/Low/Stop<br />

4 PGND - Ground Ground<br />

5 PGND - Ground Ground<br />

6 +24V2 I 24 V DC 24 V DC power supply<br />

7 THERM O Analog Fuser thermistor temperature detection signal<br />

8 HEATN I 0/24 V DC Heater lamp: On/Off<br />

9 SLEEP I 0/5 V DC Sleep mode control signal: On/Off<br />

10 EXITN O 0/5 V DC Exit sensor: On/Off<br />

11 ZCROSS O 0/5 V DC (pulse) Zero cross signal<br />

12 +24V1 O 24 V DC 24 V DC power supply<br />

13 +24V1 O 24 V DC 24 V DC power supply<br />

14 SGND - Ground Ground<br />

15 SGND - Ground Ground<br />

1 FAN O 0/12/24 V DC Cooling fan rotation: High/Low/Stop<br />

2 +24V1 O 24 V DC 24 V DC power supply for cooling fan<br />

1 THERM I Analog Fuser thermistor temperature detection signal<br />

2 +5V O 5 V DC 5 V DC power supply for fuser thermistor<br />

L Live I 110 V AC AC input<br />

120 V AC<br />

220 - 240 V AC<br />

N Neutral I 110 V AC AC input<br />

120 V AC<br />

220 - 240 V AC<br />