2G6<br />

(1) Interlock switch<br />

The interlock switch is located on the high voltage unit and opened and closed in conjunction with the front cover or the top<br />

cover via the interlock lever. This switch connects and disconnects the +24 V DC power supply line. If the front cover or the<br />

top cover is open, the interlock switch is open, and the +24 V DC to the high voltage output circuit, bias PWB, engine PWB,<br />

and the power supply unit is disconnected, deactivating the high voltage output, laser output, main motor output for safety.<br />

The cooling fan is an exception: Since the cooling fan is directly fed with +24 V DC from the power supply unit at the primary<br />

side (+24V1) of the interlock switch, the cooling fan is not deactivated even the cover is open.<br />

Top cover<br />

Projection<br />

Interlock lever<br />

Engine PWB<br />

Projection<br />

Bias<br />

PWB<br />

Power supply unit<br />

+24V2<br />

+24V3<br />

Front cover<br />

+24V2<br />

Triac, etc.<br />

+24V2<br />

High voltage<br />

output circuit<br />

Interlock<br />

switch<br />

+24 V DC<br />

output<br />

+24V1<br />

+24V1<br />

Cooling fan<br />

High voltage unit<br />

Machine left side view<br />

Figure 2-3-9 Interlock switch<br />

2-3-12