Intel Server Board S1200BT - PROconsult Data A/S
Intel Server Board S1200BT - PROconsult Data A/S
Intel Server Board S1200BT - PROconsult Data A/S
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Connector/Header Locations and Pin-outs<br />
<strong>Intel</strong>® <strong>Server</strong> <strong>Board</strong> <strong>S1200BT</strong> TPS<br />
Table 33. SAS Connector Pin-out (J2H1)<br />
Pin Signal Name Description<br />
1 GND Ground<br />
2 SATA/SAS_TX_P_C Positive side of transmit differential pair<br />
3 SATA/SAS_TX_N_C Negative side of transmit differential pair<br />
4 GND Ground<br />
5 SATA/SAS_RX_N_C Negative side of receive differential pair<br />
6 SATA/SAS_RX_P_C Positive side of receive differential pair<br />
7 GND Ground<br />
7.5.5 Serial Port Connectors<br />
The server board provides one external DB9 Serial A port (J8A1) and one internal 9-pin serial B<br />
header (J1B2). The following tables define the pin-outs.<br />
Table 34. External Serial A Port Pin-out (J8A1)<br />
Pin Signal Name Description<br />
1 SPA_DCD DCD (carrier detect)<br />
2 SPA_SIN_L RXD (receive data)<br />
3 SPA_SOUT_N TXD (Transmit data)<br />
4 SPA_DTR DTR (<strong>Data</strong> terminal ready)<br />
5 GND Ground<br />
6 SPA_DSR DSR (data set ready)<br />
7 SPA_RTS RTS (request to send)<br />
8 SPA_CTS CTS (clear to send)<br />
9 SPA_RI RI (Ring Indicate)<br />
10 NC<br />
Table 35. Internal 9-pin Serial B Header Pin-out (J1B2)<br />
Pin Signal Name Description<br />
1 SPB_DCD DCD (carrier detect)<br />
2 SPB_DSR DSR (data set ready)<br />
3 SPB_SIN_L RXD (receive data)<br />
4 SPB_RTS RTS (request to send)<br />
5 SPB_SOUT_N TXD (Transmit data)<br />
6 SPB_CTS CTS (clear to send)<br />
7 SPB_DTR DTR (<strong>Data</strong> terminal ready)<br />
8 SPB_RI RI (Ring indicate)<br />
9 SPB_EN_N Enable<br />
10 NC<br />
98<br />
<strong>Intel</strong> order number G13326-003<br />
Revision 1.0