Appendix B: Integrated BMC Sensor Tables<br />

<strong>Intel</strong>® <strong>Server</strong> <strong>Board</strong> <strong>S1200BT</strong> TPS<br />

Table 56. BMC Core Sensors<br />

Full Sensor Name<br />

(Sensor name in SDR)<br />

Power Unit Status<br />

(Pwr Unit Status)<br />

Sensor<br />

#<br />

01h<br />

Platform<br />

Applicability<br />

All<br />

Sensor Type Event/Reading Type Event Offset Triggers Contrib. To System<br />

Status<br />

Power Unit<br />

09h<br />

Sensor Specific<br />

6Fh<br />

00 - Power down<br />

04 - A/C lost<br />

05 - Soft power control<br />

failure<br />

OK<br />

Fatal<br />

Assert/Deassert<br />

As and<br />

De<br />

Readable<br />

Value/Offs<br />

ets<br />

–<br />

Event<br />

<strong>Data</strong><br />

Trig<br />

Offset<br />

A<br />

Rearm<br />

X<br />

Stand-by<br />

06 - Power unit failure<br />

00 - Fully Redundant OK<br />

01 - Redundancy lost Degraded<br />

02 - Redundancy<br />

degraded<br />

Degraded<br />

Power Unit<br />

Redundancy1<br />

(Pwr Unit Redund)<br />

02h<br />

Chassisspecific<br />

Power Unit<br />

09h<br />

Generic<br />

0Bh<br />

03 - Non-redundant:<br />

sufficient resources.<br />

Transition from full<br />

redundant state.<br />

04 – Non-redundant:<br />

sufficient resources.<br />

Transition from<br />

insufficient state.<br />

05 - Non-redundant:<br />

insufficient resources<br />

Degraded<br />

Degraded<br />

Fatal<br />

As and<br />

De<br />

–<br />

Trig<br />

Offset<br />

A<br />

X<br />

06 – Redundant:<br />

degraded from fully<br />

redundant state.<br />

Degraded<br />

07 – Redundant:<br />

Transition from nonredundant<br />

state.<br />

Degraded<br />

IPMI Watchdog 03h All Watchdog 2 Sensor Specific<br />

00 - Timer expired,<br />

status only<br />

OK As –<br />

Trig<br />

Offset<br />

A<br />

X<br />

122<br />

<strong>Intel</strong> order number G13326-003<br />

Revision 1.0