<strong>Intel</strong>® <strong>Server</strong> <strong>Board</strong> <strong>S1200BT</strong> TPS<br />

Appendix B: Integrated BMC Sensor Tables<br />

T: Threshold value<br />

• Rearm Sensors<br />

The rearm is a request for the event status for a sensor to be rechecked and updated<br />

upon a transition between good and bad states. Rearming the sensors can be done<br />

manually or automatically. This column indicates the type supported by the sensor. The<br />

following abbreviations are used in the comment column to describe a sensor:<br />

A: Auto-rearm<br />

M: Manual rearm<br />

I: Rearm by init agent<br />

• Default Hysteresis<br />

The hysteresis setting applies to all thresholds of the sensor. This column provides the<br />

count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).<br />

• Criticality<br />

Criticality is a classification of the severity and nature of the condition. It also controls the<br />

behavior of the front panel status LED.<br />

• Standby<br />

Some sensors operate on standby power. These sensors may be accessed and/or<br />

generate events when the main (system) power is off, but AC power is present.<br />