<strong>Intel</strong>® <strong>Server</strong> <strong>Board</strong> <strong>S1200BT</strong> TPS<br />
Platform Management<br />
Alerts that provide useful notification to the external software for NM management, but do not<br />
represent significant fault conditions that need to be put into the SEL, will be sent to the<br />
Integrated BMC using the IPMI Alert Immediate command. This requires that the external<br />
software application provide the NM on the ME with the alert destination and alert string<br />
information needed to properly form and send the alert. The external software must first properly<br />
configure the alert destination and string in the Integrated BMC LAN configuration using<br />
standard IPMI commands, then provide the associated selectors to the Integrated BMC using<br />
the ―Set Node Manager Alert Destination‖ OEM command.<br />
4.4.3.2 BIOS-Integreated BMC-ME Communication<br />
In this generation of platforms, the BIOS communicates directly with the ME via HECI.<br />
Revision 1.0<br />
<strong>Intel</strong> order number G13326-003<br />