<strong>Intel</strong>® <strong>Server</strong> <strong>Board</strong> <strong>S1200BT</strong> TPS<br />

Platform Management<br />

Alerts that provide useful notification to the external software for NM management, but do not<br />

represent significant fault conditions that need to be put into the SEL, will be sent to the<br />

Integrated BMC using the IPMI Alert Immediate command. This requires that the external<br />

software application provide the NM on the ME with the alert destination and alert string<br />

information needed to properly form and send the alert. The external software must first properly<br />

configure the alert destination and string in the Integrated BMC LAN configuration using<br />

standard IPMI commands, then provide the associated selectors to the Integrated BMC using<br />

the ―Set Node Manager Alert Destination‖ OEM command.<br />

4.4.3.2 BIOS-Integreated BMC-ME Communication<br />

In this generation of platforms, the BIOS communicates directly with the ME via HECI.<br />