Two type-curve matches are shown with the test data<br />

on Figure 5-71. The early-time data were best fit by a<br />

type curve characteristic <strong>of</strong> damaged (i.e., having a<br />

positive skin) wells, whereas the late-time data were<br />

best fit by a type curve characteristic <strong>of</strong> undamaged<br />

(i.e., having a neutral or no skin) wells. The two typecurve<br />

matches also provide contrasting<br />

transmissivity estimates. The transmissivity derived<br />

from the early-time match is about 4 x 10-3 ftz/day,<br />

while that from the late-time match is about 7 x<br />

10-5 ftzfday (Table 5-3). These observations indicate<br />

that the P-18 wellbore may be poorly connected<br />

hydraulically to a small portion <strong>of</strong> the Culebra having<br />

a higher transmissivity than more-distant portions.<br />

The contrast between the transmissivity <strong>of</strong> the<br />

Culebra and that <strong>of</strong> the well "skin" may decrease as<br />

the transmissivity <strong>of</strong> the Culebra decreases with<br />

distance from P-18, resulting in the neutral skin<br />

shown by the late-time data. The fact that the slope<br />

<strong>of</strong> the data on Figure 5-71 changes abruptly as<br />

opposed to smoothly appears to indicate that the<br />

change in transmissivity is discrete rather than<br />

gradational. Drilling <strong>of</strong> the borehole may have<br />

caused minor fracturing <strong>of</strong> the formation around the<br />

hole, which may have led to a slightly enhanced<br />

transmissivity in the immediate vicinity <strong>of</strong> the hole.<br />

Casing, cementing, and perforation may have<br />

resulted in a poor connection between the wellbore<br />

and the surrounding formation, resulting in the<br />

positive skin observed.<br />

Given the peculiarities in the response to the P-18<br />

slug test and the uncertainties as to their cause, the<br />

transmissivity <strong>of</strong> the Culebra at P-18 remains poorly<br />

defined. The estimate provided by the early-time<br />

type-curve match does not appear to be valid beyond<br />

the immediate vicinity (a few feet?) <strong>of</strong> the well. The<br />

transmissivity estimate provided by the late-time<br />

type-curve match may not be quantitatively reliable<br />

because the time match between the data and the<br />

type curve, which defines the transmissivity, would<br />

probably be greater, thus indicating a lower<br />

transmissivity, if the hydraulic response <strong>of</strong> the<br />

Culebra had been more consistent (i.e-,<br />

homogeneous). In summary, the transmissivity<br />

estimate from the early-time data, 4 x 10-3 ftz/day, is<br />

probably unrealistically high, but is reliably a<br />

maximum value. The estimate from the late-time<br />

data, 7 x 10-5 ft*/day, is probably more representative<br />

<strong>of</strong> the Culebra in the vicinity <strong>of</strong> P-18, but cannot be<br />

interpreted as a minimum value.<br />

5.2.2.19 ERDA-9. Two falling-head slug tests<br />

were performed in November 1986 to evaluate the<br />

transmissivity <strong>of</strong> the Culebra at ERDA-9. The first<br />

was initiated on November 20, 1986. The test lasted<br />

about 18 hr, by which time over 99% <strong>of</strong> the induced<br />

pressure differential had dissipated. Figure 5-72 is a<br />

semilog plot <strong>of</strong> the slug-test data, along with the<br />

best-fit type curve. This fit provides a transmissivity<br />

estimate <strong>of</strong> 0.45 ftZ/day for the Culebra at ERDA-9<br />

(Table 5-3). The second test began on November<br />

24, 1986, and lasted about 16 hr. A semilog plot <strong>of</strong><br />

the data from this test is presented in Figure 5-73,<br />

along with the best-fit type-curve match. This match<br />

is very similar to that used to fit the data from the first<br />

test, and provides a similar transmissivity estimate <strong>of</strong><br />

0.47 ft2/day (Table 5-3). The data from these tests<br />

are reported in Stensrud et al. (<strong>1987</strong>).<br />

5.2.2.20 Cabin Baby-1. Two falling-head slug<br />

tests were performed at Cabin Baby-1 to evaluate the<br />

transmissivity <strong>of</strong> the Culebra at that location. The first<br />

test was initiated on March 10, <strong>1987</strong> and the second<br />

was initiated on March 12, <strong>1987</strong>. Complete<br />

dissipation <strong>of</strong> the induced pressure differential was<br />

achieved during the first test, and about 99%<br />

dissipation during the second. The data from these<br />

tests are presented in Stensrud et al. (<strong>1987</strong>).<br />

Figure 5-74 is a semilog plot <strong>of</strong> the data from the first<br />

test, along with the best-fit type curve. This fit<br />

provides a transmissivity estimate <strong>of</strong> 0.28 ftzjday for<br />

the Culebra at Cabin Baby-1 (Table 5-3). The<br />

semilog plot <strong>of</strong> the data from the second test<br />

(Figure 5-75) shows an identical type-curve match<br />

with a slightly better overall fit, leading to a second<br />

transmissivity estimate <strong>of</strong> 0.28 ft*/day (Table 5-3).<br />

5.2.2.21 DOE-1. After an 8-hr step-drawdown test<br />

<strong>of</strong> the Culebra conducted at DOE-1 on May 3, 1983<br />

indicated that the productivity <strong>of</strong> the well was much<br />

higher than previously believed, a 440-hr pumping<br />

test was conducted beginning on May 6, 1983. The<br />

average pumping rate during the test was 9.93 gpm.<br />

After the pump was turned <strong>of</strong>f, pressure recovery in<br />

the well was monitored for nearly 422 hr. The fluid-<br />

100